Cited 0 times in

The use of an ultrasonic dissection device for the P1 method in prosthetic breast reconstruction

DC Field Value Language
dc.contributor.author송승용-
dc.contributor.author유대현-
dc.date.accessioned2025-02-03T09:17:40Z-
dc.date.available2025-02-03T09:17:40Z-
dc.date.issued2024-10-
dc.identifier.issn2234-0831-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/202360-
dc.description.abstractBackground The P1 method in prosthetic breast reconstruction has the advantage of preventing rippling and ensuring a smooth upper pole contour. This study presents our experience with using an ultrasonic dissection device instead of a monopolar electrocautery device for the P1 method. Methods Patients who underwent prepectoral breast reconstruction at our institution between June and September 2021 were retrospectively reviewed. Among the 39 breasts analyzed, 17 underwent the P1 procedure using an ultrasonic dissection device for the superior slip of the pectoralis major muscle, while 22 underwent P0 prepectoral breast reconstruction. We compared surgical outcomes, including operative time, presence of rippling, capsular contracture, and animation deformities, and complications such as seroma, hematoma, and mastectomy skin flap necrosis. Results Patient demographics were comparable between the groups, except for chemotherapy exposure. Rippling occurred more frequently in the P0 group (36.4% vs. 23.5%); however, capsular contracture was absent in the P1 group. Despite these observations, the differences lacked statistical significance. The average operative time was longer in the P1 group than in the P0 group (104.35 minutes vs. 90.05 minutes), although this difference was not statistically significant (P=0.095). There were no instances of postoperative hematoma, infection, implant exchange, animation deformity, or implant explantation in either group. Conclusions Using an ultrasonic energy device for additional dissection in the P1 method was non-inferior in terms of complications such as bleeding, infection, or animation deformity. The ultrasonic device can facilitate safe and effective dissection when elevating the superior pectoralis muscle slip, despite requiring additional operative time.-
dc.description.statementOfResponsibilityopen-
dc.publisherKorean Society for Aesthetic Plastic Surgery-
dc.relation.isPartOfARCHIVES OF AESTHETIC PLASTIC SURGERY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleThe use of an ultrasonic dissection device for the P1 method in prosthetic breast reconstruction-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Plastic and Reconstructive Surgery (성형외과학교실)-
dc.contributor.googleauthorMin Young Lee-
dc.contributor.googleauthorJoo Yeop Lee-
dc.contributor.googleauthorDae Hyun Lew-
dc.contributor.googleauthorSeung Yong Song-
dc.identifier.doi10.14730/aaps.2024.01221-
dc.contributor.localIdA02032-
dc.contributor.localIdA02459-
dc.relation.journalcodeJ00210-
dc.identifier.eissn2287-5603-
dc.subject.keywordMammaplasty-
dc.subject.keywordUltrasonic waves-
dc.subject.keywordSurgery-
dc.subject.keywordBreast implants-
dc.contributor.alternativeNameSong, Seung Yong-
dc.contributor.affiliatedAuthor송승용-
dc.contributor.affiliatedAuthor유대현-
dc.citation.volume30-
dc.citation.number4-
dc.citation.startPage126-
dc.citation.endPage131-
dc.identifier.bibliographicCitationARCHIVES OF AESTHETIC PLASTIC SURGERY, Vol.30(4) : 126-131, 2024-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Plastic and Reconstructive Surgery (성형외과학교실) > 1. Journal Papers

qrcode