Cited 0 times in
Development and demonstration of the protective efficacy of a convertible respiratory barrier enclosure: a simulation study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김지훈 | - |
dc.contributor.author | 홍주영 | - |
dc.date.accessioned | 2025-02-03T08:54:34Z | - |
dc.date.available | 2025-02-03T08:54:34Z | - |
dc.date.issued | 2024-03 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/201990 | - |
dc.description.abstract | Objective: The efficacy of previously developed respiratory barrier enclosures to limit healthcare workers' exposure to aerosols from COVID-19 patients remains unclear; in addition, the design of these devices is unsuitable for transportation or other emergency procedures. Therefore, we developed a novel negative pressure respiratory isolator to improve protection from patient-generated aerosols and evaluated its protective effect in conversion to systemic isolator. Methods: This in vitro study simulated droplets by nebulizing 1% glycerol + 99% ethanol solution. We performed cardiopulmonary resuscitation (CPR) and converted a respiratory barrier enclosure into a systemic isolator with a respiratory barrier as well as a respiratory barrier with negative pressure generator (NPG), which were compared with control and room air. During the procedure, particles were counted for 30 seconds and the count was repeated 10 times. Results: During CPR, the total number of particles in the respiratory barrier with NPG (280,529; interquartile range [IQR], 205,263-359,195; P=0.970) was similar to that in the control (308,789; IQR, 175,056-473,276). Using NPG with a respiratory barrier reduced the number of particles to 27,524 (IQR, 26,703- 28,905; P=0.001). Particle number during conversion of the respiratory barrier into a systemic isolator was also lower than in the control (25,845; IQR, 19,391- 29,772; P=0.001). Conclusion: The novel isolator was converted to a systemic isolator without air leakage. The aerosol-blocking effect of the isolator was quantified using a particle counter during CPR. Further studies comparing the barrier effect of isolators within various pressure differentials are warranted. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Korean Society of Emergency Medicine | - |
dc.relation.isPartOf | CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Development and demonstration of the protective efficacy of a convertible respiratory barrier enclosure: a simulation study | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Emergency Medicine (응급의학교실) | - |
dc.contributor.googleauthor | Min Ho Park | - |
dc.contributor.googleauthor | Ki Sub Sung | - |
dc.contributor.googleauthor | Ji Hoon Kim | - |
dc.contributor.googleauthor | Jinwoo Myung | - |
dc.contributor.googleauthor | Ju Young Hong | - |
dc.identifier.doi | 10.15441/ceem.23.067 | - |
dc.contributor.localId | A05321 | - |
dc.contributor.localId | A05442 | - |
dc.relation.journalcode | J02980 | - |
dc.identifier.eissn | 2383-4625 | - |
dc.identifier.pmid | 38018073 | - |
dc.subject.keyword | Aerosol box | - |
dc.subject.keyword | Cardiopulmonary resuscitation | - |
dc.subject.keyword | Infection control | - |
dc.subject.keyword | Intubation | - |
dc.subject.keyword | Personal protective equipment | - |
dc.contributor.alternativeName | Kim, Ji Hoon | - |
dc.contributor.affiliatedAuthor | 김지훈 | - |
dc.contributor.affiliatedAuthor | 홍주영 | - |
dc.citation.volume | 11 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 59 | - |
dc.citation.endPage | 67 | - |
dc.identifier.bibliographicCitation | CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, Vol.11(1) : 59-67, 2024-03 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.