Cited 0 times in

Advanced mathematical modeling for preciseestimation of CT energy spectrum using a calibration phantom

Authors
 Jeong Heon Kim  ;  So Hyun Ahn  ;  Kwang Woo Park  ;  Jin Sung Kim 
Citation
 PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, Vol.126 : 104819, 2024-10 
Journal Title
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
ISSN
 1120-1797 
Issue Date
2024-10
MeSH
Calibration ; Humans ; Models, Theoretical ; Monte Carlo Method* ; Phantoms, Imaging* ; Tomography, X-Ray Computed* / instrumentation
Keywords
Calibration phantom ; Energy spectrum ; Mass attenuation coefficient ; Mathematical model
Abstract
Purpose: This research aims to develop an advanced mathematical model using a CT calibration phantom to accurately estimate the CT energy spectrum in clinical settings, enhancing imaging quality and patient dose management.

Methods: Data were collected from a CT scanner using a CT calibration phantom at various energy levels (80, 100, 120, and 135 kVp). The data was optimized to refine the energy spectrum model, followed by cross-validation with Monte Carlo simulations.

Results: The developed model demonstrated high precision in estimating the CT energy spectrum at all tested energy levels, with R-squared values above 0.9738 and an R-squared value of 0.9829 at 100 kVp. The model also showed low Normalized Root Mean Square Deviation (NRMSD) ranging from 0.6698 % to 1.8745 %. The Mean Energy Difference (ΔE) between the estimated and simulated spectrum consistently remained under 0.01 keV. These results were comparable to recent studies, which reported higher NRMSD and ΔE.

Conclusions: This study presents a significantly improved model for estimating the CT energy spectrum, offering greater accuracy than existing models. Its strengths include high precision and the use of standard equipment and algorithmic values. While the current use of 13 plugs is adequate, incorporating plugs with varied densities could enhance accuracy. This model has potential for improving imaging quality and optimizing patient dosing in clinical applications. Future trends may include extending energy spectrum estimation to megavoltage domains and integrating technologies like EPID and MVCT for better dose distribution prediction in high-energy photon beam therapy.
Full Text
https://www.sciencedirect.com/science/article/pii/S1120179724010767?via%3Dihub
DOI
10.1016/j.ejmp.2024.104819
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jinsung(김진성) ORCID logo https://orcid.org/0000-0003-1415-6471
Park, Kwang Woo(박광우) ORCID logo https://orcid.org/0000-0002-9843-7985
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/201786
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links