Cited 0 times in

Feasibility and safety report on robotic assistance for cervical pedicle screw fixation: a cadaveric study

Authors
 Seungjun Ryu  ;  Byeong-Jin Ha  ;  Sunjin Yoon  ;  Chang Kyu Lee  ;  Dong Ah Shin  ;  Keung-Nyun Kim  ;  Seong Yi 
Citation
 SCIENTIFIC REPORTS, Vol.14(1) : 10881, 2024-05 
Journal Title
SCIENTIFIC REPORTS
Issue Date
2024-05
MeSH
Cadaver* ; Cervical Vertebrae* / surgery ; Feasibility Studies* ; Female ; Humans ; Male ; Pedicle Screws* ; Robotic Surgical Procedures* / instrumentation ; Robotic Surgical Procedures* / methods ; Spinal Fusion / instrumentation ; Spinal Fusion / methods
Abstract
This cadaveric study aimed to evaluate the safety and usability of a novel robotic system for posterior cervical pedicle screw fixation. Three human cadaveric specimens and C2-T3 were included. Freshly frozen human cadaver specimens were prepared and subjected to robot-assisted posterior cervical pedicle screw fixation using the robotic system. The accuracy of screw placement, breach rate, and critical structure violations were evaluated. The results were statistically compared with those of previous studies that used different robotic systems for cervical pedicle screw fixation. The robotic system demonstrated a high accuracy rate in screw placement. A significant number of screws were placed within predetermined safe zones. The total entry offset was 1.08 ± 0.83 mm, the target offset was 1.86 ± 0.50 mm, and the angle offset was 2.14 ± 0.77°. Accuracy rates comparable with those of previous studies using different robotic systems were achieved. The system was also feasible, allowing precise navigation and real-time feedback during the procedure. This cadaveric study validated the safety and usability of the novel robotic system for posterior cervical pedicle screw fixation. The system exhibited high precision in screw placement, and the results support the extension of the indications for robot-assisted pedicle screw fixation from the lumbar spine to the cervical spine.
Files in This Item:
T202406610.pdf Download
DOI
10.1038/s41598-024-60435-6
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Keung Nyun(김긍년)
Shin, Dong Ah(신동아) ORCID logo https://orcid.org/0000-0002-5225-4083
Yoon, Seon Jin(윤선진) ORCID logo https://orcid.org/0000-0002-3255-5081
Yi, Seong(이성)
Lee, Chang Kyu(이창규)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/201117
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links