Cited 3 times in

Comparative Analysis of the Performance of Electroencephalogram Parameters for Monitoring the Depth of Sedation During Remimazolam Target-Controlled Infusion

Authors
 Myung Il Bae  ;  Jayyoung Bae  ;  Young Song  ;  Minjae Kim  ;  Dong Woo Han 
Citation
 ANESTHESIA AND ANALGESIA, Vol.138(6) : 1295-1303, 2024-06 
Journal Title
ANESTHESIA AND ANALGESIA
ISSN
 0003-2999 
Issue Date
2024-06
MeSH
Adult ; Aged ; Anesthesia, Spinal / methods ; Benzodiazepines* / administration & dosage ; Benzodiazepines* / pharmacokinetics ; Conscious Sedation / methods ; Consciousness Monitors ; Electroencephalography* / drug effects ; Electroencephalography* / methods ; Female ; Humans ; Hypnotics and Sedatives* / administration & dosage ; Hypnotics and Sedatives* / pharmacokinetics ; Infusions, Intravenous ; Intraoperative Neurophysiological Monitoring / methods ; Male ; Middle Aged ; Monitoring, Intraoperative / methods ; Prospective Studies
Abstract
Background: The changes in hypnotic indicators in remimazolam sedation remain unclear. We investigated the correlation of the electroencephalogram (EEG) parameters with the effect-site remimazolam concentration and the depth of sedation in patients receiving a target-controlled infusion of remimazolam.

Methods: This prospective observational study enrolled 35 patients (32 analyzed) who underwent lower extremity varicose vein surgery or lower extremity orthopedic surgery under spinal anesthesia. We administered remimazolam by target-controlled infusion using the pharmacokinetic model introduced by Schüttler et al. The EEG data were continuously recorded, including the bispectral index (BIS), patient state index (PSI), spectral edge frequency (SEF), and raw EEG signals. The relative beta ratio (RBR), defined as log (spectral power [30-47 Hz]/spectral power [11-20 Hz]), was obtained by analyzing raw EEG. The level of sedation corresponding to each effect-site remimazolam concentration was assessed using the Modified Observer's Assessment of Alertness/Sedation (MOAA/S). The prediction probability (Pk) and Spearman's correlation coefficients (R) were calculated between effect-site remimazolam concentration, MOAA/S, and EEG parameters.

Results: BIS and PSI showed significantly higher Pk for effect-site remimazolam concentration (Pk = 0.76 [0.72-0.79], P < .001 for BIS; Pk = 0.76 [0.73-0.79], P < .001 for PSI) compared to RBR (Pk = 0.71 [0.68-0.74], P < .001) and SEF (Pk = 0.58 [0.53-0.63], P = .002). BIS, PSI, and RBR showed significantly higher correlation coefficients for effect-site remimazolam concentration (R = -0.70 [-0.78 to -0.63], P < .001 for BIS; R = -0.72 [-0.79 to -0.66], P < .001 for PSI; R = -0.61 [-0.69 to -0.54], P < .001 for RBR) compared to SEF (R = -0.22 [-0.36 to -0.08], P = .002). BIS and PSI also had significantly higher Pk and correlation coefficients for MOAA/S (Pk = 0.81 [0.79-0.83], P < .001; R = 0.84 [0.81-0.88], P < .001 for BIS) (Pk = 0.80 [0.78-0.83], P < .001; R = 0.82 [0.78-0.87], P < .001 for PSI) compared to RBR (Pk = 0.74 [0.72-0.77], P < .001; R = 0.72 [0.65-0.78], P < .001) and SEF (Pk = 0.55 [0.50-0.59], P = .041; R = 0.13 [-0.01 to 0.27], P = .067).

Conclusions: BIS, PSI, and RBR showed an acceptable correlation with the effect-site remimazolam concentration and depth of sedation in this study, suggesting that these EEG-derived parameters are potentially reliable hypnotic indicators during remimazolam sedation. BIS and PSI showed superior performance as hypnotic indicators to RBR and SEF in patients receiving target-controlled infusion of remimazolam.
Full Text
https://journals.lww.com/anesthesia-analgesia/fulltext/2024/06000/comparative_analysis_of_the_performance_of.19.aspx
DOI
10.1213/ANE.0000000000006718
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers
Yonsei Authors
Bae, Myung Il(배명일)
Bae, Jayyoung(배재영)
Song, Young(송영) ORCID logo https://orcid.org/0000-0003-4597-387X
Han, Dong Woo(한동우) ORCID logo https://orcid.org/0000-0002-8757-663X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/200310
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links