dc.description.abstract | Purpose: To investigate the clinical outcomes of new hydrophobic trifocal intraocular lens with hydroxyethyl methacrylate in the Korean population Methods: This prospective, multicenter, and observational study evaluated the clinical outcomes of 80 eyes of 40 patients with age-related cataract underwent cataract surgery using CNWT (Clareon PanOptix). Assessment included monocular and binocular uncorrected distance visual acuity, corrected distance visual acuity, uncorrected intermediate visual acuity (at 60cm), near visual acuity (at 40 and 33 cm), uncorrected defocus curves, questionnaires evaluating photic phenomena, spectacle independence, and spectacle free satisfaction. Results: At postoperative 3 months, mean uncorrected binocular visual acuities were 0.04, 0.04, 0.03 logarithm of the minimum angle of resolution (logMAR) at far, intermediate, and near distances, respectively. All patients achieved uncorrected binocular visual acuity of 0.2 logMAR or better. Monocular and binocular defocus curve indicated a mean visual acuity of 0.2 logMAR or better at the defocus range of +1.0 to – 3.0 diopters (100 to 33 cm) and +1.0 to – 3.5 diopters (100 to 28 cm). High spectacle independence was observed at all distances, with 37.5% patients reporting photic phenomena. Conclusions: The Clareon PanOptix intraocular lens has shown positive clinical outcomes, providing a viable option for cataract surgery. These lenses effectively address patients’ visual needs, especially in intermediate and near distance tasks, reducing dependence on glasses. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | KJO | - |
dc.relation.isPartOf | Korean Journal of Ophthalmology | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Cataract / complications | - |
dc.subject.MESH | Cataract / physiopathology | - |
dc.subject.MESH | Cataract Extraction | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Follow-Up Studies | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Lens Implantation, Intraocular | - |
dc.subject.MESH | Lenses, Intraocular | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Methacrylates | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Multifocal Intraocular Lenses | - |
dc.subject.MESH | Patient Satisfaction | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Prosthesis Design | - |
dc.subject.MESH | Refraction, Ocular / physiology | - |
dc.subject.MESH | Surveys and Questionnaires | - |
dc.subject.MESH | Treatment Outcome | - |
dc.subject.MESH | Vision, Binocular / physiology | - |
dc.subject.MESH | Visual Acuity* / physiology | - |
dc.title | Clinical Outcomes of a New Hydrophobic Trifocal Intraocular Lens with Hydroxyethyl Methacrylate in Cataract Surgery: A Prospective Multicenter Study | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학교실) | - |
dc.contributor.googleauthor | Eunhui Jo | - |
dc.contributor.googleauthor | Bokyung Kim | - |
dc.contributor.googleauthor | Tae-Im Kim | - |
dc.contributor.googleauthor | Mee Kum Kim | - |
dc.contributor.googleauthor | Chul Young Choi | - |
dc.identifier.doi | 10.3341/kjo.2023.0140 | - |
dc.contributor.localId | A01080 | - |
dc.relation.journalcode | J02931 | - |
dc.identifier.eissn | 2092-9382 | - |
dc.identifier.pmid | 38644651 | - |
dc.subject.keyword | Cataract | - |
dc.subject.keyword | Multifocal intraocular lenses | - |
dc.subject.keyword | Presbyopia | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | 김태임 | - |
dc.citation.volume | 38 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 212 | - |
dc.citation.endPage | 220 | - |
dc.identifier.bibliographicCitation | Korean Journal of Ophthalmology, Vol.38(3) : 212-220, 2024-06 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.