3 11

Cited 0 times in

Comparison of Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance During Transcatheter Aortic Valve Replacement

Authors
 Sang-Hyup Lee  ;  Seunguk Oh  ;  Young-Guk Ko  ;  Yong-Joon Lee  ;  Seung-Jun Lee  ;  Sung-Jin Hong  ;  Chul-Min Ahn  ;  Jung-Sun Kim  ;  Byeong-Keuk Kim  ;  Kyu-Yong Ko Iksung Cho  ;  Chi Young Shim  ;  Geu-Ru Hong  ;  Donghoon Choi  ;  Myeong-Ki Hong 
Citation
 KOREAN CIRCULATION JOURNAL, Vol.54(2) : 63-75, 2024-02 
Journal Title
KOREAN CIRCULATION JOURNAL
ISSN
 1738-5520 
Issue Date
2024-02
Keywords
Aortic valve stenosis ; Cardiac imaging techniques ; Conscious sedation ; Transcatheter aortic valve replacement
Abstract
Background and objectives: Evidence regarding the efficacy and safety of intracardiac echocardiography (ICE) for guidance during transcatheter aortic valve replacement (TAVR) is limited. This study aimed to compare the clinical efficacy and safety of ICE versus transesophageal echocardiography (TEE) for guiding TAVR.

Methods: This prospective cohort study included patients who underwent TAVR from August 18, 2015, to June 31, 2021. Eligible patients were stratified by echocardiographic modality (ICE or TEE) and anesthesia mode (monitored anesthesia care [MAC] or general anesthesia [GA]). Primary outcome was the 1-year composite of all-cause mortality, rehospitalization for cardiovascular cause, or stroke, according to the Valve Academic Research Consortium-3 (VARC-3) definition. Propensity score matching was performed, and study outcomes were analyzed for the matched cohorts.


Results: Of the 359 eligible patients, 120 patients were matched for the ICE-MAC and TEE-GA groups, respectively. The incidence of primary outcome was similar between matched groups (18.3% vs. 20.0%; adjusted hazard ratio, 0.94; 95% confidence interval [CI], 0.53-1.68; p=0.843). ICE-MAC and TEE-GA also had similar incidences of moderate-to-severe paravalvular regurgitation (PVR) (4.2% vs. 5.0%; adjusted odds ratio, 0.83; 95% CI, 0.23-2.82; p=0.758), new permanent pacemaker implantation, and VARC-3 types 2-4 bleeding.


Conclusions: ICE was comparable to TEE for guidance during TAVR for the composite clinical efficacy outcome, with similar incidences of moderate-to-severe PVR, new permanent pacemaker implantation, and major bleeding. These results suggest that ICE could be a safe and effective alternative echocardiographic modality to TEE for guiding TAVR.
Files in This Item:
T202403130.pdf Download
DOI
10.4070/kcj.2023.0195
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Go, Kyu-Yong(고규용)
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Shim, Chi Young(심지영) ORCID logo https://orcid.org/0000-0002-6136-0136
Ahn, Chul-Min(안철민) ORCID logo https://orcid.org/0000-0002-7071-4370
Lee, Sanghyup(이상협)
Lee, Seung-Jun(이승준) ORCID logo https://orcid.org/0000-0002-9201-4818
Lee, Yong Joon(이용준)
Cho, Ik Sung(조익성)
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Geu Ru(홍그루) ORCID logo https://orcid.org/0000-0003-4981-3304
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
Hong, Sung Jin(홍성진) ORCID logo https://orcid.org/0000-0003-4893-039X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/199785
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links