41 101

Cited 1 times in

Three-Dimensional Peri-Implant Tissue Changes in Immediately vs. Early Placed Tapered Implants Restored with Two Different Ceramic Materials-1 Year Results

Authors
 Malin Strasding  ;  Yuwon Jeong  ;  Laurent Marchand  ;  Stefan P Hicklin  ;  Irena Sailer  ;  Minji Sun  ;  Hyeonjong Lee 
Citation
 MATERIALS, Vol.16(16) : 5636, 2023-08 
Journal Title
MATERIALS
Issue Date
2023-08
Keywords
bone-level tapered ; clinical study ; dental implants ; digital dentistry ; early placement ; immediate placement ; multi-center RCT ; peri-implant tissue ; volumetric
Abstract
Background: A prospective multi-center randomized controlled clinical trial was performed to digitally analyze tissue volume changes in immediately and early placed implants with simultaneous bone augmentation restored with two different all-ceramic materials. Methods: A total of 60 patients received 60 bone-level tapered implants (BLT, Straumann AG) immediately (n = 30) or early placed, 8–10 weeks after tooth extraction, (n = 30). Implants were restored with all-ceramic single crowns fabricated out of zirconia (Lava Plus, 3M), or lithium disilicate (E.max CAD, Ivoclar Vivadent AG) bonded to titanium base abutments (Variobase for Cerec, Straumann AG). Impressions were taken at baseline (BL), 6 and 12 months, and STL data were used to define an area of interest (AOI) to analyze peri-implant volume changes and midfacial recessions. Results: For immediate placement, a mean volume loss of −5.56 mm3 (±5.83 mm3) was found at 6 months, and of −6.62 mm3 (±6.56 mm3) at 12 months. For early placement, a mean volume loss of −1.99 mm3 (±5.82 mm3) at 6 months, and of −3.7 mm3 (±5.62 mm3) at 12 months was found. The differences in volume loss at 12 months between the two implant placement protocols were significant (p = 0.005). In both groups, mean midfacial recessions of 0.48 mm (±0.52) occurred. Conclusions: A more pronounced peri-implant volume loss can be expected 12 months after immediate implant placement compared with early placement. © 2023 by the authors.
Files in This Item:
T999202707.pdf Download
DOI
10.3390/ma16165636
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Sun, Minji(선민지)
Lee, Hyeonjong(이현종) ORCID logo https://orcid.org/0000-0002-1669-2975
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/198507
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links