42 116

Cited 0 times in

Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study

DC Field Value Language
dc.contributor.author김지훈-
dc.contributor.author명진우-
dc.contributor.author홍주영-
dc.date.accessioned2024-01-31T05:47:53Z-
dc.date.available2024-01-31T05:47:53Z-
dc.date.issued2023-03-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/197904-
dc.description.abstractObjective This study aimed to introduce a novel negative pressure aerosol box (Carrycure Isola-tor) and to test its efficiency and limitations, with the hope of suggesting improvements and further directions. Methods A novel aerosol box (Carrycure Isolator) was invented. A single-center, randomized, crossover simulation study of 28 emergency medicine physicians was designed. Three trials of each participant using an intubation manikin were conducted, including intubation without the aerosol box (trial A), intubation with the aerosol box (trial B), and intubation with the aerosol box after familiarization (trial C). The primary endpoint was the time to intubation. The secondary endpoints were first-attempt success, number of attempts, percentage of glottic opening score, and Cormack-Lehane view. Collected data were statistically analyzed for their signifi-cance. Results The median times to intubation of trials A, B, and C were 30.5 (interquartile range [IQR], 28.0–40.0 seconds), 59.0 (IQR, 50.0–75.5 seconds), and 34.0 seconds (IQR, 30.5–47.0 seconds), respectively. Post hoc analysis showed that the time to intubation in trial B was significantly longer than that in trial A (P<0.05), while that the time to intubation in trial C was significantly shorter than that in trial B (P< 0.05). Results concerning secondary endpoints showed similar patterns. Participants reported performing intubation with Carrycure Isolator to be relatively dif-ficult, necessitating significant arm movement and view restrictions while increasing their time to intubation. Conclusion Physicians took a longer time to intubate a manikin using the Carrycure Isolator, a novel negative pressure aerosol box. However, the time was improved after a period of familiar-ization. © 2023 The Korean Society of Emergency Medicine.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorean Society of Emergency Medicine-
dc.relation.isPartOfCLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEfficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Emergency Medicine (응급의학교실)-
dc.contributor.googleauthorYoungbin Park-
dc.contributor.googleauthorKi Sub Sung-
dc.contributor.googleauthorJi Hoon Kim-
dc.contributor.googleauthorJinwoo Myung-
dc.contributor.googleauthorJu Young Hong-
dc.identifier.doi10.15441/ceem.22.342-
dc.contributor.localIdA05321-
dc.contributor.localIdA05919-
dc.contributor.localIdA05442-
dc.relation.journalcodeJ02980-
dc.identifier.eissn2383-4625-
dc.identifier.pmid36652941-
dc.subject.keywordCrossover studies-
dc.subject.keywordEfficiency-
dc.subject.keywordIntratracheal intubation-
dc.subject.keywordPatient isolators-
dc.subject.keywordSimulation training-
dc.contributor.alternativeNameKim, Ji Hoon-
dc.contributor.affiliatedAuthor김지훈-
dc.contributor.affiliatedAuthor명진우-
dc.contributor.affiliatedAuthor홍주영-
dc.citation.volume10-
dc.citation.number1-
dc.citation.startPage44-
dc.citation.endPage51-
dc.identifier.bibliographicCitationCLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, Vol.10(1) : 44-51, 2023-03-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Emergency Medicine (응급의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.