63 99

Cited 2 times in

Comparing dusting and fragmenting efficiency using the new SuperPulsed thulium fiber laser versus a 120 W Holmium:YAG laser

Authors
 Ben H Chew  ;  Kyo Chul Koo  ;  Abdulghafour Halawani  ;  Colin J Lundeen  ;  Bodo E Knudsen  ;  Wilson R Molina 
Citation
 INVESTIGATIVE AND CLINICAL UROLOGY, Vol.64(3) : 265-271, 2023-05 
Journal Title
INVESTIGATIVE AND CLINICAL UROLOGY
ISSN
 2466-0493 
Issue Date
2023-05
MeSH
Holmium ; Humans ; Lasers, Solid-State* / therapeutic use ; Lithotripsy* ; Lithotripsy, Laser* / methods ; Thulium
Keywords
Holmium ; Lithotripsy, laser ; Thulium ; Ureteroscopy ; Urinary stones
Abstract
Purpose: Holmium:YAG laser lithotripsy requires high amperage power and has an upper limit of frequency and a minimal fiber size. The technology utilizing thulium-doped fiber offers low pulse energy settings and high pulse frequencies up to 2,400 Hz. We compared the novel SuperPulsed thulium fiber laser (SOLTIVE™; Olympus) to a commercially available 120 W Ho:YAG laser.

Materials and methods: Bench-top testing was conducted with 125 mm3 standardized BegoStones (Bego USA). Time to ablate the stone into particles <1 mm was recorded for efficiency calculations. Finite energy was delivered, and resulting particle sizes were measured to determine fragmentation (0.5 kJ) and dusting (2 kJ) efficiencies. Remaining mass or number of fragments were measured to compare efficacy.

Results: SOLTIVE™ was faster at ablating stones to particles <1 mm (2.23±0.22 mg/s, 0.6 J 30 Hz short pulse) compared to Ho:YAG laser (1.78±0.44 mg/s, 0.8 J 10 Hz short pulse) (p<0.001). Following 0.5 kJ of energy in fragmentation testing, fewer particles >2 mm remained using SOLTIVE™ than Ho:YAG laser (2.10 vs. 7.20 fragments). After delivering 2 kJ, dusting (1.05±0.08 mg/s) was faster using SOLTIVE™ (0.1 J 200 Hz short pulse) than 120 W 0.46±0.09 mg/s (0.3 J 70 Hz Moses) (p=0.005). SOLTIVE™ (0.1 J 200 Hz) produced more dust particles <0.5 mm (40%) compared to 24% produced by the P120 W laser at 0.3 J 70 Hz Moses and 14% at 0.3 J 70 Hz long pulse (p=0.015).

Conclusions: The efficacy of SOLTIVE™ is superior to the 120 W Ho:YAG laser by producing smaller dust particles and fewer fragments. Further studies are warranted.
Files in This Item:
T202306809.pdf Download
DOI
10.4111/icu.20230071
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Urology (비뇨의학교실) > 1. Journal Papers
Yonsei Authors
Koo, Kyo Chul(구교철) ORCID logo https://orcid.org/0000-0001-7303-6256
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/197410
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links