47 131

Cited 0 times in

Intracorporeal modified delta-shaped gastroduodenostomy during 2-port distal gastrectomy: technical aspects and short-term outcomes

Authors
 Sejin Lee  ;  Jeong Ho Song  ;  Sung Hyun Park  ;  Minah Cho  ;  Yoo Min Kim  ;  Woo Jin Hyung  ;  Hyoung-Il Kim 
Citation
 ANNALS OF SURGICAL TREATMENT AND RESEARCH, Vol.105(3) : 172-177, 2023-09 
Journal Title
ANNALS OF SURGICAL TREATMENT AND RESEARCH
ISSN
 2288-6575 
Issue Date
2023-09
Keywords
Gastroenterostomy ; Minimally invasive surgical procedures
Abstract
Purpose: Surgeons have become increasingly interested in reduced-port gastrectomy to minimize trauma while maintaining oncologic safety. Although gastroduodenostomy has the benefits of better nutritional outcomes and fewer postoperative complications than other types of reconstruction, gastroduodenostomy is not a preferred option for reduced-port distal gastrectomy because of technical difficulties. In this study, we describe our intracorporeal modified delta-shaped gastroduodenostomy technique, which is easily applicable during 2-port distal gastrectomy.

Methods: We retrospectively reviewed our database of 30 consecutive patients with gastric cancer who underwent 2-port distal gastrectomy with intracorporeal modified delta-shaped gastroduodenostomy from October 2016 to May 2021. In this reduced-port approach, we used a Tropian Single port (TROPIAN TECH) via a 25-mm transumbilical incision and a 12-mm port at the right flank. All anastomoses were performed using a 60-mm endolinear stapler. We used 3 additional sutures to provide proper traction and support for the anastomosis.

Results: Mean ± standard deviation of operation time was 148.9 ± 34.7 minutes; reconstruction time was 13.2 ± 4.6 minutes; estimated blood loss was 29.3 ± 44.4 mL; and length of hospital stay was 4.5 ± 1.2 postoperative days. A total of 11 patients (36.7%) had a Clavien-Dindo grade I or grade II complication, and there were no grade IIIa or higher complications.

Conclusion: Intracorporeal modified delta-shaped gastroduodenostomy was safely performed via a 2-port approach, resulting in acceptable surgical outcomes and no major complications.
Files in This Item:
T202306824.pdf Download
DOI
10.4174/astr.2023.105.3.172
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Yoo Min(김유민)
Kim, Hyoung Il(김형일) ORCID logo https://orcid.org/0000-0002-6134-4523
Park, Sung Hyun(박성현)
Cho, Minah(조민아) ORCID logo https://orcid.org/0000-0003-3011-5813
Hyung, Woo Jin(형우진) ORCID logo https://orcid.org/0000-0002-8593-9214
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/197203
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links