69 128

Cited 0 times in

Comparison of pulmonary vein isolation using cryoballoon, high-power short-duration, and conventional radiofrequency ablation for atrial fibrillation: a propensity score-weighted study

Authors
 Hanjin Park  ;  Je-Wook Park  ;  Daehoon Kim  ;  Hee Tae Yu  ;  Tae-Hoon Kim  ;  Jae-Sun Uhm  ;  Boyoung Joung  ;  Moon-Hyoung Lee  ;  Chun Hwang  ;  Hui-Nam Pak 
Citation
 FRONTIERS IN CARDIOVASCULAR MEDICINE, Vol.10 : 1238363, 2023-10 
Journal Title
FRONTIERS IN CARDIOVASCULAR MEDICINE
Issue Date
2023-10
Keywords
atrial fibrillation ; catheter ablation ; cryoballoon ablation ; heart rate variability ; high-power short-duration ablation
Abstract
Background: The comparative efficacy, saftey, and heart rate variability (HRV) parameters after pulmonary vein isolation using cryoballoon (Cryo-PVI), high-power short-duration (HPSD-PVI), and conventional radiofrequency ablation (conventional-PVI) for atrial fibrillation (AF) is unclear.

Materials and methods: In this propensity score-weighted, retrospective analysis of a single-center cohort, we analyzed 3,395 patients (26.2% female, 74.5% paroxysmal AF) who underwent AF catheter ablation without an empirical left atrial ablation. Procedural factors, recurrence rates, complication rates, and the post-procedural HRV parameters were compared across the Cryo-PVI (n = 625), HPSD-PVI (n = 748), and conventional-PVI (n = 2,022) groups.

Results: Despite the shortest procedural time in the Cryo-PVI group (74 min for Cryo-PVI vs. 104 min for HPSD-PVI vs. 153 min for conventional-PVI, p < 0.001), the major complication (p = 0.906) and clinical recurrence rates were similar across the three ablation groups (weighted log-rank, p = 0.824). However, the Cryo-PVI group was associated with a significantly lower risk of recurrent AF in patients with paroxysmal AF [weighted hazard ratio (WHR) 0.57, 95% confidence interval (CI) 0.37-0.86], whereas it was associated with a higher risk of recurrent AF in patients with persistent AF (WHR 1.41, 95% CI 1.06-1.89, p for interaction of <0.001) compared with the conventional-PVI group. In the subgroup analysis for the HRV, the Cryo-PVI group had the highest low-frequency-to-high-frequency ratio at 1-year post-procedure, whereas the HPSD-PVI group had the lowest low-frequency-to-high-frequency ratio at 1-year post-procedure (p < 0.001).

Conclusions: The Cryo-PVI group had better rhythm outcomes in patients with paroxysmal AF but worse rhythm outcomes in patients with persistent AF and a higher long-term post-procedural sympathetic nervous activity and sympatho-vagal balance compared with the conventional-PVI group.
Files in This Item:
T202306156.pdf Download
DOI
10.3389/fcvm.2023.1238363
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Dae Hoon(김대훈) ORCID logo https://orcid.org/0000-0002-9736-450X
Kim, Tae-Hoon(김태훈) ORCID logo https://orcid.org/0000-0003-4200-3456
Park, Je Wook(박제욱)
Pak, Hui Nam(박희남) ORCID logo https://orcid.org/0000-0002-3256-3620
Uhm, Jae Sun(엄재선) ORCID logo https://orcid.org/0000-0002-1611-8172
Yu, Hee Tae(유희태) ORCID logo https://orcid.org/0000-0002-6835-4759
Lee, Moon-Hyoung(이문형) ORCID logo https://orcid.org/0000-0002-7268-0741
Joung, Bo Young(정보영) ORCID logo https://orcid.org/0000-0001-9036-7225
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/196737
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links