167 317

Cited 0 times in

Cited 0 times in

Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity

Authors
 Han, Su Chul 
Citation
 PLOS ONE, Vol.17(3), 2022-03 
Article Number
 e0266110 
Journal Title
PLOS ONE
ISSN
 1932-6203 
Issue Date
2022-03
Abstract
The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (N = 26) were sampled in total OSLDs (N = 46) depending on the radiation sensitivity for this study. After irradiating doses from 0.5 to 40 Gy at fixed intervals in a standard environment, the dose response of a reference OSLD (N = 5) was determined through the reading process at each dose. The dose-response curves obtained from the reference OSLD were fitted according to the dose. In the dose range below 3 Gy, a linear function was used to determine the relationship between dose and the OSLD response. Quadratic and cubic functions were applied for dose ranges of up to 15 Gy and 40 Gy, respectively. Test OSLDs (N = 21) were evaluated at various doses (2.5 to 30 Gy) using different fitting functions, according to dose ranges. When doses from 0.5 Gy to 3.0 Gy were curve-fitted to the linear function, the relationship was y = 70278.0x - 3125.3 (r(2) = 0.999). When doses of up to 15 Gy were curve-fitted to the quadratic function, the relationship was y = 628.6x(2) + 70444.6x - 6142.3 (r(2) = 0.999). Furthermore, when doses of up to 40 Gy were curve-fitted to the cubic function, the relation was y = -15.5x(3) + 527.3x(2) + 75059.6x - 16260.3 (r(2) = 0.998). Test OSLDs were evaluated for various dose ranges based on the above equation. It was confirmed that the average difference was 0.86 +/- 0.27%, and it was evaluated that the largest difference occurred at 30 Gy (2.24 +/- 0.24%). In this study, we prove that measurements using the OSLD at various dose ranges, including high doses, will be possible through the application of an in-house software program and a correction process.
DOI
10.1371/journal.pone.0266110
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Han, Su Chul(한수철)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/194664
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links