150 309

Cited 0 times in

연속적인 임상 혈액 배양 양성 검체를 이용한 QMAC-dRAST의 성능 평가

Other Titles
 Performance Evaluation of QMAC-dRAST Using Consecutive Positive Clinical Blood Culture Samples 
Authors
 최희강  ;  김대원  ;  권미정  ;  변정현  ;  진봉환  ;  홍기호  ;  이혁민  ;  용동은 
Citation
 Laboratory Medicine Online, Vol.13(2) : 78-84, 2023-04 
Journal Title
Laboratory Medicine Online
Issue Date
2023-04
Keywords
Antimicrobial susceptibility testing ; Blood culture ; Bacteremia
Abstract
Background: Bacteremia is life-threatening to patients, with a case fatality rate of 30–40%. The QMAC-dRAST system (QuantaMatrix, Republic of Korea), which is based on time-lapse imaging technology, can generate antimicrobial susceptibility testing (AST) results earlier than conventional equipment. Here, we evaluated the performance of QMAC-dRAST for positive blood culture samples.

Methods: In total, 204 isolates were collected from positive blood cultures, with 104 Gram-positive cocci (GPC) and 100 Gram-negative rods (GNR), including Staphylococcus spp., Enterococcus spp., Enterobacteriaceae, Pseudomonas aeruginosa, and Acinetobacter spp. Before and after improvement of the AST algorithm, 67 GPC isolates and 72 GNR isolates were tested and their results were compared. In the final test, 37 GPC and 28 GNR were added, and the agreement rates between QMAC-dRAST and Vitek 2 were analyzed using 204 samples. To resolve discrepant AST results between two systems, broth microdilution tests were performed.

Results: In the first and second tests with 67 GPC and 72 GNR, the categorical agreement (CA) between QMAC-dRAST and Vitek 2 was increased from 92.7% and 96.2% to 94.3% and 96.5% by updating the AST algorithm, respectively. For all 204 samples, the agreement rates were 94.5% and 95.4% for CA; 4.8% and 0.6% for very major errors; 2.5% and 2.0% for major errors; and 2.1% and 3.0% for minor errors.

Conclusions: The QMAC-dRAST system has reliable performance and the advantage of faster AST reporting than conventional methods. This system will demonstrate more acceptable agreement rates with conventional AST systems in the future by improving AST algorithms.
Files in This Item:
T202302526.pdf Download
DOI
10.47429/lmo.2023.13.2.78
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Yong, Dong Eun(용동은) ORCID logo https://orcid.org/0000-0002-1225-8477
Lee, Hyuk Min(이혁민) ORCID logo https://orcid.org/0000-0002-8523-4126
Hong, Ki Ho(홍기호) ORCID logo https://orcid.org/0000-0002-5700-9036