Authors
 Deok-Gie Kim  ;  Jun Young Lee  ;  Jhii-Hyun Ahn  ;  Taesic Lee  ;  Minseob Eom  ;  Hyun Seok Cho  ;  Jihye Ku 
Citation
 EUROPEAN RADIOLOGY, Vol.33(4) : 2367-2377, 2023-04 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2023-04
MeSH
Contrast Media ; Elasticity Imaging Techniques* ; Graft Rejection / diagnostic imaging ; Humans ; Kidney / diagnostic imaging ; Kidney / pathology ; Kidney Transplantation* ; Transplantation, Homologous ; Ultrasonography / methods
Keywords
Color Doppler ultrasonography ; Contrast agent ; Graft rejection ; Kidney transplantation ; Ultrasonography
Abstract
Objectives: This study aimed to investigate the predictive efficacy of shear-wave elastography, superb microvascular imaging (SMI), and CEUS for allograft rejection in kidney transplants without graft dysfunction.

Methods: From January 2021 to November 2021, 72 consecutive patients who underwent both allograft biopsy and ultrasound were evaluated. Blood test results were obtained within a week of the ultrasound examinations, which were performed before the protocol biopsy. Resistive index (RI), tissue viscoelasticity, vascular index, and quantitative CEUS parameters were measured. Patients were divided based on biopsy results into the rejection and non-rejection groups.

Results: Among the 72 patients, 21 patients had pathological characteristics of acute rejection. RI of allograft was significantly higher in the rejection group (p = 0.007), compared to the non-rejection group. There were no significant between-group differences in vascular indices of SMI, mean elasticity, and mean viscosity. Meanwhile, among the parameters obtained by the time-intensity curve on CEUS, the cortical and medullary ratios of average contrast signal intensity, peak enhancement, wash-in area AUC, wash-in perfusion index, wash-out AUC, and wash-in and wash-out AUC were significantly different between the two groups (p < 0.05). In the receiver operating characteristic curve analysis for predicting allograft rejection, the AUC was 0.853 for the combination of six CEUS parameters, RI, and blood urea nitrogen.

Conclusions: Among non-invasive quantitative ultrasound measurements, CEUS parameters are the most useful for diagnosing subclinical allograft rejection. Furthermore, the combination of CEUS parameters, RI, and blood urea nitrogen may be helpful for the early detection of renal allograft rejection.
Full Text
https://link.springer.com/article/10.1007/s00330-022-09260-x
DOI
10.1007/s00330-022-09260-x
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Deok Gie(김덕기)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/194129
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links