147 345

Cited 1 times in

Three-dimensional soft tissue landmark detection with marching cube algorithm

DC Field Value Language
dc.contributor.author박선형-
dc.contributor.author유형석-
dc.contributor.author최성환-
dc.contributor.author최윤정-
dc.date.accessioned2023-03-22T02:14:20Z-
dc.date.available2023-03-22T02:14:20Z-
dc.date.issued2023-01-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/193551-
dc.description.abstractCurrent method of analyzing three-dimensional soft tissue data, especially in the frontal view, is subjective and has poor reliability. To overcome this limitation, the present study aimed to introduce a new method of analyzing soft tissue data reconstructed by marching cube algorithm (Program S) and compare it with a commercially available program (Program A). Cone-beam computed tomography images of 42 patients were included. Two orthodontists digitized six landmarks (pronasale, columella, upper and lower lip, right and left cheek) twice using both programs in two-week intervals, and the reliability was compared. Furthermore, computer-calculated point (CC point) was developed to evaluate whether human error could be reduced. The results showed that the intra- and inter-examiner reliability of Program S (99.7-100% and 99.9-100%, respectively) were higher than that of Program A (64.0-99.9% and 76.1-99.9%, respectively). Moreover, the inter-examiner difference of coordinate values and distances for all six landmarks in Program S was lower than Program A. Lastly, CC point was provided as a consistent single point. Therefore, it was validated that this new methodology can increase the intra- and inter-examiner reliability of soft tissue landmark digitation and CC point can be used as a landmark to reduce human error.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherNature Publishing Group-
dc.relation.isPartOfSCIENTIFIC REPORTS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAlgorithms*-
dc.subject.MESHCephalometry / methods-
dc.subject.MESHCone-Beam Computed Tomography / methods-
dc.subject.MESHHumans-
dc.subject.MESHImaging, Three-Dimensional* / methods-
dc.subject.MESHLip / diagnostic imaging-
dc.subject.MESHReproducibility of Results-
dc.titleThree-dimensional soft tissue landmark detection with marching cube algorithm-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Orthodontics (교정과학교실)-
dc.contributor.googleauthorYoonjung Lee-
dc.contributor.googleauthorJi-Min Lee-
dc.contributor.googleauthorSun-Hyung Park-
dc.contributor.googleauthorYoon Jeong Choi-
dc.contributor.googleauthorSung-Hwan Choi-
dc.contributor.googleauthorJae Joon Hwang-
dc.contributor.googleauthorHyung-Seog Yu-
dc.identifier.doi10.1038/s41598-023-28792-w-
dc.contributor.localIdA01506-
dc.contributor.localIdA02532-
dc.contributor.localIdA04083-
dc.contributor.localIdA04139-
dc.relation.journalcodeJ02646-
dc.identifier.eissn2045-2322-
dc.identifier.pmid36707701-
dc.contributor.alternativeNamePark, Sun Hyung-
dc.contributor.affiliatedAuthor박선형-
dc.contributor.affiliatedAuthor유형석-
dc.contributor.affiliatedAuthor최성환-
dc.contributor.affiliatedAuthor최윤정-
dc.citation.volume13-
dc.citation.number1-
dc.citation.startPage1544-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, Vol.13(1) : 1544, 2023-01-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.