175 305

Cited 12 times in

Comparison Between 3-Dimensional-Printed Titanium and Polyetheretherketone Cages: 1-Year Outcome After Minimally Invasive Transforaminal Interbody Fusion

Authors
 Do-Yeon Kim  ;  O-Hyuk Kwon  ;  Jeong-Yoon Park 
Citation
 NEUROSPINE, Vol.19(3) : 524-532, 2022-09 
Journal Title
NEUROSPINE
ISSN
 2586-6583 
Issue Date
2022-09
Keywords
3-dimensional-printed titanium ; Fusion rate ; Minimally invasive transforaminal lumbar interbody fusion ; Polyetheretherketone
Abstract
Objective: Three-dimensional (3D)-printed titanium implants have been developed recently, but the utility is not yet proven. The aim of this study was to compare 3D-printed titanium and polyetheretherketone (PEEK) implants after minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF).

Methods: Between October 2018 and September 2021, we retrospectively analyzed 83 patients who underwent single-level MIS-TLIF (3D-printed titanium, 40; PEEK, 43). Radiologic parameters were assessed with x-ray and computed tomography (CT) at postoperative 1 week, 6 months, and 1 year. Clinical status was evaluated using Oswestry Disability Index, visual analogue scale score, and Bridwell fusion grading was assessed on 6-month and 1-year postoperative CT.

Results: There were no differences between the 2 groups in demographics and clinical outcomes. At 1-year of follow-up, the reported 3D-printed titanium fusion grades were grade I: 77.5% (31 patients), grade II: 17.5% (7 patients), and grade III: 5% (2 patients). The PEEK fusion grades were grade I: 51.2% (22 patients), grade II: 41.9% (18 patients), and grade III: 7.0% (3 patients). For overall fusion rate (grade I + II), there was no difference between the 2 cages (95.0% vs. 93.0%, p = 0.705), but grade I was reported at a higher incidence in 3D-printed titanium than PEEK (77.5% vs. 51.2%, p = 0.013). There was no difference between cages based on subsidence and complications.

Conclusion: There were no significant differences in the overall fusion rate for MIS-TLIF surgery between 3D-printed titanium and PEEK, but the fusion grade was better in 3D-printed titanium than in PEEK. Long-term follow-up is required to verify the effectiveness.
Files in This Item:
T9992022626.pdf Download
DOI
10.14245/ns.2244140.070
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kwon, Ohyuk(권오혁)
Park, Jeong Yoon(박정윤) ORCID logo https://orcid.org/0000-0002-3728-7784
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/193397
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links