161 291

Cited 0 times in

Improvement of Ultrasound Image Quality Using Non-Local Means Noise-Reduction Approach for Precise Quality Control and Accurate Diagnosis of Thyroid Nodules

Authors
 Kyuseok Kim  ;  Nuri Chon  ;  Hyun-Woo Jeong  ;  Youngjin Lee 
Citation
 INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, Vol.19(21) : 13743, 2022-10 
Journal Title
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
ISSN
 1661-7827 
Issue Date
2022-10
MeSH
Algorithms ; Humans ; Image Processing, Computer-Assisted / methods ; Phantoms, Imaging ; Quality Control ; Signal-To-Noise Ratio ; Thyroid Nodule* / diagnostic imaging ; Ultrasonography
Keywords
accurate diagnosis of thyroid nodules ; noise reduction ; non-local means approach ; quantitative evaluation of image quality ; ultrasound quality control
Abstract
This study aimed to improve the quality of ultrasound images by modeling an algorithm using a non-local means (NLM) noise-reduction approach to achieve precise quality control and accurate diagnosis of thyroid nodules. An ATS-539 multipurpose phantom was used to scan the dynamic range and gray-scale measurement regions, which are most closely related to the noise level. A convex-type 3.5-MHz frequency probe is used for scanning according to ATS regulations. In addition, ultrasound images of human thyroid nodules were obtained using a linear probe. An algorithm based on the NLM noise-reduction approach was modeled based on the intensity and relative distance of adjacent pixels in the image, and conventional filtering methods for image quality improvement were designed as a comparison group. When the NLM algorithm was applied to the image, the contrast-to-noise ratio and coefficient of variation values improved by 28.62% and 19.54 times, respectively, compared with those of the noisy images. In addition, the image improvement efficiency of the NLM algorithm was superior to that of conventional filtering methods. Finally, the applicability of the NLM algorithm to human thyroid images using a high-frequency linear probe was validated. We demonstrated the efficiency of the proposed algorithm in ultrasound images and the possibility of capturing improved images in the dynamic range and gray-scale region for quality control parameters.
Files in This Item:
T202300560.pdf Download
DOI
10.3390/ijerph192113743
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Kyuseok(김규석)