0 202

Cited 7 times in

Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants

Authors
 Soyeon Park  ;  Jieun Park  ;  Inyeong Kang  ;  Hyeonjong Lee  ;  Gunwoo Noh 
Citation
 COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, Vol.221 : 106852, 2022-06 
Journal Title
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
ISSN
 0169-2607 
Issue Date
2022-06
MeSH
Biomechanical Phenomena ; Bone Remodeling / physiology ; Computer Simulation ; Dental Implants* ; Finite Element Analysis ; Stress, Mechanical
Keywords
Bone quality ; Bone remodeling ; Dental implants ; Finite element analysis
Abstract
Background and objective: While an accurate assessment of the biomechanical stability of implants is essential in dental prosthesis planning and associated treatment assurance, the bone remodeling process is often ignored in biomechanical studies using finite element (FE) analysis. In this study, we aimed to analyze the significance of assessing the bone remodeling process in FE analysis for evaluating the biomechanical stability of dental implants. We compared the FE results considering the bone remodeling process with FE results simulated using commonly used conditions, with no considerations of the bone remodeling process.

Methods: The mathematical model proposed by Komarova et al. was used to calculate cell population dynamics and changes in bone density at a discrete site. The model was implemented in the FE software ABAQUS, using the UMAT subroutine. Three-dimensional FE models were constructed for two types of bone (III and IV) and three values of implant diameter (4.0, 4.5, and 5.0 mm). An average biting force of 50 N in the vertical direction was applied during the bone remodeling process for 150 days. Afterwards, the maximum biting force of 200 N in the 30° oblique direction was applied to evaluate the stability of the implant systems.

Results: To understand the impact of bone remodeling on the resultant mechanical responses, we focused on peri-implant cancellous bone based on two parameters: apparent density change and microstrain distribution. The bone density decreased by an average of 5.3 % after implantation, and it was the lowest on the 6th day. The average density increases of the peri-implant cancellous bone were 264.4 kgm3 (bone type III) and 220.0 kgm3 (bone type IV) over 150 days. For the bone stability analysis, the maximum principal strain in the peri-implant bone was used to evaluate the bone stability. If the bone remodeling process is ignored, then the bone volume within the fatigue failure range of the microstrain differs significantly from that if the bone remodeling process is considered, i.e., 60 % higher for bone type III and 33.4 % lower for bone type IV than when the bone remodeling process is considered.

Conclusions: The FE result without considering the bone remodeling process could be considered a conservative criterion for bone type III. However, in bone type IV, the FE result without considering the bone remodeling process tends to underestimate the risks. The bone remodeling process is more affected by the initial bone quality than the implant diameter.
Full Text
https://www.sciencedirect.com/science/article/pii/S0169260722002346?via%3Dihub
DOI
10.1016/j.cmpb.2022.106852
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Hyeonjong(이현종) ORCID logo https://orcid.org/0000-0002-1669-2975
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/191542
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.