Cited 8 times in
Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김응권 | - |
dc.contributor.author | 김태임 | - |
dc.contributor.author | 서경률 | - |
dc.contributor.author | 전익현 | - |
dc.date.accessioned | 2022-12-22T02:11:53Z | - |
dc.date.available | 2022-12-22T02:11:53Z | - |
dc.date.issued | 2022-06 | - |
dc.identifier.issn | 1011-8942 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/191491 | - |
dc.description.abstract | Purpose: To compare anterior biometry measurements using placido-scanning-slit topography, rotating Scheimpflug tomography, and swept-source optical coherence tomography. Methods: A retrospective review consisted of 80 eyes of 49 participants who underwent anterior chamber depth (ACD), central corneal thickness (CCT), and keratometry examination on the same day. We used placido-scanning-slit topography (ORBscan II), rotating Scheimpflug tomography (Pentacam HR), and swept-source optical coherence tomography (CASIA SS1000). The intraclass correlation coefficients and Bland-Altman plots were used to evaluate the agreement and differences between measurements. Results: The mean ACD values were 2.88 ± 0.43, 2.82 ± 0.50, and 2.68 ± 0.44 mm; and the mean CCT values were 536.96 ± 31.19, 543.79 ± 31.04, and 561.41 ± 32.60 μm; and the mean keratometry (Km) were 43.81 ± 1.69, 43.81 ± 1.77, and 44.65 ± 1.95 diopters; as measured by CASIA SS-1000, Pentacam HR, and ORBscan II, respectively. Among the three devices, ACD was deepest to shallowest in the order of CASIA SS-1000, Pentacam HR, and ORBscan II (p < 0.05). The CCT was thickest to thinnest in the order of ORBscan II, Pentacam HR, and CASIA SS-1000 (p < 0.05). No significant differences in Km values were examined between CASIA SS-1000 and Pentacam HR, whereas ORBscan II overestimated Km with a statistically significant difference compared to the other two devices. Conclusions: High level of agreement was found between CASIA SS-1000 and Pentacam HR for anterior parameters, including ACD, CCT, and Km, suggesting interchangeability. However, ORBscan II measurements differed considerably with the measurements obtained from the other two devices; therefore, it should not be used interchangeably. However, further studies with repeatability test should be considered in order to elucidate the reliability of each device. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | KJO | - |
dc.relation.isPartOf | Korean Journal of Ophthalmology | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Biometry* / methods | - |
dc.subject.MESH | Cornea / diagnostic imaging | - |
dc.subject.MESH | Corneal Topography / methods | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Tomography, Optical Coherence* / methods | - |
dc.title | Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학교실) | - |
dc.contributor.googleauthor | Soyoung Ryu | - |
dc.contributor.googleauthor | Sook Hyun Yoon | - |
dc.contributor.googleauthor | Ikhyun Jun | - |
dc.contributor.googleauthor | Kyoung Yul Seo | - |
dc.contributor.googleauthor | Eung Kweon Kim | - |
dc.contributor.googleauthor | Tae-Im Kim | - |
dc.identifier.doi | 10.3341/kjo.2021.0120 | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.contributor.localId | A01870 | - |
dc.contributor.localId | A03541 | - |
dc.relation.journalcode | J02931 | - |
dc.identifier.eissn | 2092-9382 | - |
dc.identifier.pmid | 35527529 | - |
dc.subject.keyword | Anterior | - |
dc.subject.keyword | Anterior eye segment | - |
dc.subject.keyword | Placido-scanning-slit | - |
dc.subject.keyword | Scheimpflug camera | - |
dc.subject.keyword | Swept source optical coherence tomography | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | 김응권 | - |
dc.contributor.affiliatedAuthor | 김태임 | - |
dc.contributor.affiliatedAuthor | 서경률 | - |
dc.contributor.affiliatedAuthor | 전익현 | - |
dc.citation.volume | 36 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 264 | - |
dc.citation.endPage | 273 | - |
dc.identifier.bibliographicCitation | Korean Journal of Ophthalmology, Vol.36(3) : 264-273, 2022-06 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.