Cited 37 times in
Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00)
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김태임 | - |
dc.date.accessioned | 2022-09-14T01:45:45Z | - |
dc.date.available | 2022-09-14T01:45:45Z | - |
dc.date.issued | 2021-11 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/190600 | - |
dc.description.abstract | Purpose: This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis Symfony, Johnson & Johnson Vision, Santa Ana, CA, US) to a novel, higher-order aspheric monofocal IOL (ICB00; Tecnis Eyhance, Johnson & Johnson Vision, Santa Ana, CA, US) which uses the same platform and material. Methods: Medical records of patients undergoing cataract surgery with ZXR00 or ICB00 implantation between March 2020 and January 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA); corrected distance VA; and optical quality parameters were the main outcome measures. Results: Among the 174 enrolled patients, 72 and 102 received the ZXR00 and ICB00, respectively. The average patient ages were 59.6 ± 10.6 (range: 49 to 70) and 65.2 ± 8.2 (range: 45 to 82) years in the ZXR00 and ICB00 groups, respectively, with significantly older patients in the ICB00 group. The other baseline parameters were not different for the 2 groups. Compared to the ICB00 group, the ZXR00 group showed markedly superior near VA (P < 0.05) at 3 months postoperatively. In terms of optical quality, ICB00 was, statistically, significantly superior to ZXR00. Conclusions: The ZXR00 showed remarkable near vision and defocus curve smoothness, while the ICB00 achieved better optical quality. The 2 IOLs had comparable distance and intermediate vision. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Chinese University of Hong Kong | - |
dc.relation.isPartOf | ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Lens Implantation, Intraocular | - |
dc.subject.MESH | Lenses, Intraocular* | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Patient Satisfaction | - |
dc.subject.MESH | Phacoemulsification* | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Prosthesis Design | - |
dc.title | Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00) | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학교실) | - |
dc.contributor.googleauthor | Young Joon Jeon | - |
dc.contributor.googleauthor | Yisang Yoon | - |
dc.contributor.googleauthor | Tae-Im Kim | - |
dc.contributor.googleauthor | Kyungmin Koh | - |
dc.identifier.doi | 10.1097/APO.0000000000000439 | - |
dc.contributor.localId | A01080 | - |
dc.relation.journalcode | J04278 | - |
dc.identifier.eissn | 2162-0989 | - |
dc.identifier.pmid | 34608065 | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | 김태임 | - |
dc.citation.volume | 10 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 542 | - |
dc.citation.endPage | 547 | - |
dc.identifier.bibliographicCitation | ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, Vol.10(6) : 542-547, 2021-11 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.