316 956

Cited 0 times in

Cited 9 times in

Procedural Characteristics of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention and Their Clinical Implications

Authors
 Lee, Seung-Yul  ;  Zhang, Jun-Jie  ;  Mintz, Gary S.  ;  Hong, Sung Jin  ;  Ahn , Chul Min  ;  Kim, Jung Sun  ;  Kim, Byeong Keuk  ;  Ko, Young Guk  ;  Choi, Dong Hoon  ;  Jang, Yangsoo  ;  Kan, Jing  ;  Pan, Tao  ;  Gao, Xiaofei  ;  Ge, Zhen  ;  Chen, Shao-Liang  ;  Hong, Myeong Ki 
Citation
 Journal of the American Heart Association, Vol.11(14), 2022-07 
Article Number
 e025258 
Journal Title
JOURNAL OF THE AMERICAN HEART ASSOCIATION
ISSN
 2047-9980 
Issue Date
2022-07
Keywords
coronary artery disease ; percutaneous coronary intervention ; ultrasound
Abstract
BACKGROUND: Despite the clinical benefits to intravascular ultrasound (IVUS) guidance for percutaneous coronary intervention (PCI), most patients with coronary artery disease undergo angiography-guided PCI alone in the real-world setting. We sought to investigate the procedural characteristics of IVUS-guided PCI and their clinical outcomes, as compared with angiography-guided PCI. METHODS AND RESULTS: This was a cohort study using patient-level data from the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) and ULTIMATE (Intravascular Ultrasound Guided Drug Eluting Stents Implantation in All-Corners Coronary Lesions) clinical trials. A total of 2848 patients with 3872 native coronary lesions were included and procedural characteristics assessed by quantitative coronary angiography (QCA) were compared between IVUS and angiography guidance. Stent-to-reference vessel diameter ratio (ie, QCA stent sizing) was greater (1.11 +/- 0.16 versus 1.07 +/- 0.14, P<0.001) and high-pressure postdilation was more frequently performed (83.7% versus 75.4%, P<0.001) with IVUS guidance, whereas residual stent edge dissections were more frequent in lesions treated with IVUS guidance (4.6% versus 0.7%, P<0.001). Given the dissection risk, optimal QCA stent sizing for IVUS guidance was a stent-to-QCA reference vessel diameter ratio >= 1.1 to <1.3. Among 1424 patients (1969 lesions) treated with angiography guidance, QCA stent sizing <1.0 was observed in 651 (33.1%) lesions, while QCA stent sizing >= 1.1 to <1.3 was observed in only 526 (26.7%) lesions. Under angiography guidance, patients with both QCA stent sizing >= 1.1 to <1.3 and high-pressure postdilation (235 of 1424, 16.5%) had a lower risk of 3-year target lesion failure compared with others (hazard ratio, 0.532; 95% CI, 0.293-0.966 [P=0.038]). CONCLUSIONS: IVUS-guided PCI resulted in larger QCA-assessed stent sizing and more frequent postdilation with high-pressure inflations. These procedures may further improve long-term clinical outcomes in patients undergoing PCI without IVUS.
DOI
10.1161/JAHA.122.025258
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Ahn, Chul-Min(안철민)
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
Hong, Sung Jin(홍성진) ORCID logo https://orcid.org/0000-0003-4893-039X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/189568
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links