A Prototype of a Stereoacuity Test Using a Head-Mounted Display

DC Field Value Language
dc.contributor.authorCho, Hyuna-
dc.contributor.authorKim, Hyosun-
dc.contributor.authorMok, Rang Kyun-
dc.contributor.authorPark, Sung Eun-
dc.contributor.authorChoi, Wung Rak-
dc.contributor.authorHan, Seung Han-
dc.contributor.authorHan , Jin u-
dc.date.accessioned2022-08-23T00:29:29Z-
dc.date.available2022-08-23T00:29:29Z-
dc.date.created2022-09-14-
dc.date.issued2022-03-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/189459-
dc.description.abstractPurpose: To evaluate the test-retest reliability of a contour-based stereoacuity test using a head-mounted display (HMD) and compare it with other stereotests. Methods: Thirty-two healthy adults aged 23-47 years were recruited from a tertiary hospital between August 2017 and July 2018. Two separate contour-based circles (crossed disparity: 135-1,350 arcsecs) were generated on a high-resolution phone display (Galaxy S7; Samsung, Seoul, Korea) using an HMD (Galaxy Gear VR). Two images were independently projected to each eye as graded circles with a random dot background. The results of the new HMD stereotest were compared to those of the standard Randot and TNO stereotests. The test-retest reliability was assessed using the Bland-Altman plot and Cohen's kappa statistics. Results: Among the 32 study participants, 17 (53%) were males and the mean age was 30.1 +/- 4.8 years (range: 23-47). The mean stereoacuity was 160.3 +/- 53.5 arcsecs in the first HMD stereotest (HMD1), 28.4 +/- 12.5 arcsecs in the Randot stereotest, 96.1 +/- 83.5 arcsecs in the TNO stereotest, and 143.3 +/- 47.7 arcsecs in the second HMD stereotest (HMD2). The Bland-Altman plot showed a mean difference of 0.042 (-0.189 to +0.272, 95% limits of agreement) between HMD1 and HMD2. The reliability analysis showed an intraclass correlation coefficient of 0.499 (p = 0.022) and agreement of 81.25% in Cohen's kappa statistics (Cohen's kappa index = 0.119, p = 0.017). Conclusions: The HMD stereotest without monocular cues showed fair test-retest reliability and reproducibility. Further studies using a high resolution display are needed to confirm the validity of the HMD stereotest.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY(대한안과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleA Prototype of a Stereoacuity Test Using a Head-Mounted Display-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthorCho, Hyuna-
dc.contributor.googleauthorKim, Hyosun-
dc.contributor.googleauthorMok, Rang Kyun-
dc.contributor.googleauthorPark, Sung Eun-
dc.contributor.googleauthorChoi, Wung Rak-
dc.contributor.googleauthorHan, Seung Han-
dc.contributor.googleauthorHan , Jin u-
dc.identifier.doi10.3341/jkos.2022.63.3.301-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordHead-mounted display-
dc.subject.keywordStereopsis-
dc.subject.keywordVirtual reality-
dc.contributor.alternativeNamePark, Sung Eun-
dc.contributor.affiliatedAuthorCho, Hyuna-
dc.contributor.affiliatedAuthorPark, Sung Eun-
dc.contributor.affiliatedAuthorChoi, Wung Rak-
dc.contributor.affiliatedAuthorHan, Seung Han-
dc.contributor.affiliatedAuthorHan , Jin u-
dc.identifier.scopusid2-s2.0-85128833660-
dc.identifier.wosid000790398500011-
dc.citation.volume63-
dc.citation.number3-
dc.citation.startPage301-
dc.citation.endPage308-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY(대한안과학회지), Vol.63(3) : 301-308, 2022-03-
dc.identifier.rimsid75647-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorHead-mounted display-
dc.subject.keywordAuthorStereopsis-
dc.subject.keywordAuthorVirtual reality-
dc.subject.keywordPlusTNO-
dc.subject.keywordPlusCHILDREN-
dc.subject.keywordPlusFRISBY-
dc.subject.keywordPlusRANDOT-
dc.type.docTypeArticle-
dc.identifier.kciidART002820043-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.relation.journalResearchAreaOphthalmology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.