Cited 0 times in
머리 부분 탑재형 디스플레이를 이용한 입체시검사법
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박성은 | - |
dc.contributor.author | 최웅락 | - |
dc.contributor.author | 한승한 | - |
dc.contributor.author | 한진우 | - |
dc.date.accessioned | 2022-08-23T00:29:29Z | - |
dc.date.available | 2022-08-23T00:29:29Z | - |
dc.date.issued | 2022-03 | - |
dc.identifier.issn | 0378-6471 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/189459 | - |
dc.description.abstract | Purpose To evaluate the test-retest reliability of a contour-based stereoacuity test using a head-mounted display (HMD) and compare it with other stereotests. Methods Thirty-two healthy adults aged 23-47 years were recruited from a tertiary hospital between August 2017 and July 2018. Two separate contour-based circles (crossed disparity: 135-1,350 arcsecs) were generated on a high-resolution phone display (Galaxy S7; Samsung, Seoul, Korea) using an HMD (Galaxy Gear VR). Two images were independently projected to each eye as graded circles with a random dot background. The results of the new HMD stereotest were compared to those of the standard Randot and TNO stereotests. The test-retest reliability was assessed using the Bland-Altman plot and Cohen’s kappa statistics. Results Among the 32 study participants, 17 (53%) were males and the mean age was 30.1 ± 4.8 years (range: 23-47). The mean stereoacuity was 160.3 ± 53.5 arcsecs in the first HMD stereotest (HMD1), 28.4 ± 12.5 arcsecs in the Randot stereotest, 96.1 ± 83.5 arcsecs in the TNO stereotest, and 143.3 ± 47.7 arcsecs in the second HMD stereotest (HMD2). The Bland-Altman plot showed a mean difference of 0.042 (-0.189 to +0.272, 95% limits of agreement) between HMD1 and HMD2. The reliability analysis showed an intraclass correlation coefficient of 0.499 (p = 0.022) and agreement of 81.25% in Cohen’s kappa statistics (Cohen’s kappa index = 0.119, p = 0.017). Conclusions The HMD stereotest without monocular cues showed fair test-retest reliability and reproducibility. Further studies using a high resolution display are needed to confirm the validity of the HMD stereotest. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한안과학회 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY(대한안과학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 머리 부분 탑재형 디스플레이를 이용한 입체시검사법 | - |
dc.title.alternative | A Prototype of a Stereoacuity Test Using a Head-Mounted Display | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학교실) | - |
dc.contributor.googleauthor | 조현아 | - |
dc.contributor.googleauthor | 김효선 | - |
dc.contributor.googleauthor | 목랑균 | - |
dc.contributor.googleauthor | 박성은 | - |
dc.contributor.googleauthor | 최웅락 | - |
dc.contributor.googleauthor | 한승한 | - |
dc.contributor.googleauthor | 한진우 | - |
dc.identifier.doi | 10.3341/jkos.2022.63.3.301 | - |
dc.contributor.localId | A05758 | - |
dc.contributor.localId | A04123 | - |
dc.contributor.localId | A04303 | - |
dc.contributor.localId | A04329 | - |
dc.relation.journalcode | J01838 | - |
dc.identifier.eissn | 2092-9374 | - |
dc.subject.keyword | Head-mounted display | - |
dc.subject.keyword | Stereopsis | - |
dc.subject.keyword | Virtual reality | - |
dc.contributor.alternativeName | Park, Sung Eun | - |
dc.contributor.affiliatedAuthor | 박성은 | - |
dc.contributor.affiliatedAuthor | 최웅락 | - |
dc.contributor.affiliatedAuthor | 한승한 | - |
dc.contributor.affiliatedAuthor | 한진우 | - |
dc.citation.volume | 63 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 301 | - |
dc.citation.endPage | 308 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.63(3) : 301-308, 2022-03 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.