0 343

Cited 0 times in

Preliminary results of a single photon emission computed tomography (SPECT) detector for inspection of spent fuel assembly

Authors
 Min Kyu Baek  ;  Hyun Joon Choi  ;  Kyu Bom Kim  ;  Jae Joon Ahn  ;  Chul Hee Min  ;  Yong Hyun Chung 
Citation
 RADIATION PHYSICS AND CHEMISTRY, Vol.197 : 110162, 2022-08 
Journal Title
RADIATION PHYSICS AND CHEMISTRY
ISSN
 0969-806X 
Issue Date
2022-08
Keywords
Single photon emission computed tomography (SPECT) ; Silicon photomultipliers (SiPM) ; Bismuth germanate (BGO) ; Spent fuel assembly
Abstract
SPECT systems are being used by international safeguards organizations for the measurement for structural evaluation of spent fuel assemblies. However, the low sensitivity still limits the verification of spent fuel assemblies within a short measurement time (1–2 h per assembly). In this study, the SPECT detector was optimized and evaluated to identify the structure of spent fuel. The detector module consists of 64 one-dimensional (1-D) multi-slit collimators and 1-D pixelated scintillators coupled to SiPMs. We evaluated and optimized the light collection efficiency and energy resolution according to the shape of scintillator (Trapezoid, Rectangular), and reflector materials (Paint, Teflon tape, BaSO4) by Geant4 Application for Tomographic Emission (GATE) simulation and experiment. As a result, the trapezoidal scintillator coated with BaSO4 showed the highest light collection efficiency among the six models in GATE simulation and in experiments. The spent fuel rods were imaged using trapezoidal scintillator coated with BaSO4, and 1-D projections and line profiles were obtained in order to distinguish the source location. In this study, the scintillator structure and reflector material variables were optimized using Monte Carlo simulation to measure 662 keV gamma-ray of 137Cs for inspection of spent fuel assembly using the SPECT system. In order to confirm the imaging potential of the spent fuel assembly, the detector performance was evaluated using unused fuel rods for testing. The performance of the detector for fuel rod identification has been proven, and we expect that the optimized detector module will contribute to the rapid verification of the spent fuel assembly compared to conventional systems.
Full Text
https://www.sciencedirect.com/science/article/pii/S0969806X22002043
DOI
10.1016/j.radphyschem.2022.110162
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Kyu Bom(김규범) ORCID logo https://orcid.org/0000-0002-3025-375X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/189271
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links