Ex Vivo Evaluation of Mechanical Anisotropic Tissues with High-Frequency Ultrasound Shear Wave Elastography

Authors
 Seungyeop Lee  ;  Lucy Youngmin Eun  ;  Jae Youn Hwang  ;  Yongsoon Eun 
Citation
 SENSORS, Vol.22(3) : 978, 2022-01 
Journal Title
SENSORS
Issue Date
2022-01
MeSH
Animals ; Anisotropy ; Elasticity Imaging Techniques* ; Mechanical Phenomena ; Phantoms, Imaging ; Swine ; Ultrasonography
Keywords
cartilage experiment ; elastography ; heart experiment ; high-frequency ultrasound ; mechanical anisotropy ; mechanical wave imaging
Abstract
The use of imaging devices to assess directional mechanics of tissues is highly desirable. This is because the directional mechanics depend on fiber orientation, and altered directional mechanics are closely related to the pathological status of tissues. However, measuring directional mechanics in tissues with high-stiffness is challenging due to the difficulty of generating localized displacement in these tissues using acoustic radiation force, a general method for generating displacement in ultrasound-based elastography. In addition, common ultrasound probes do not provide rotational function, which makes the measurement of directional mechanics inaccurate and unreliable. Therefore, we developed a high-frequency ultrasound mechanical wave elastography system that can accommodate a wide range of tissue stiffness and is also equipped with a motorized rotation stage for precise imaging of directional mechanics. A mechanical shaker was applied to the elastography system to measure tissues with high-stiffness. Phantom and ex vivo experiments were performed. In the phantom experiments, the lateral and axial resolution of the system were determined to be 144 μm and 168 μm, respectively. In the ex vivo experiments, we used swine heart and cartilage, both of which are considered stiff. The elastography system allows us to acquire the directional mechanics with high angular resolution in the heart and cartilage. The results demonstrate that the developed elastography system is capable of imaging a wide range of tissues and has high angular resolution. Therefore, this system might be useful for the diagnostics of mechanically anisotropic tissues via ex vivo tests.
Files in This Item:
T202201041.pdf Download
DOI
10.3390/s22030978
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pediatrics (소아과학교실) > 1. Journal Papers
Yonsei Authors
Eun, Lucy Youngmin(은영민) ORCID logo https://orcid.org/0000-0002-4577-3168
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/188388
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links