214 399

Cited 0 times in

우리나라의 구내 치근단 및 파노라마방사선촬영의 진단참고수준

Authors
 김은경  ;  한원정  ;  최진우  ;  허민석  ;  이삼선  ;  김경아  ;  이완  ;  김진수  ;  윤숙자  ;  정연화  ;  김규태  ;  전국진  ;  한진우  ;  안서영 
Citation
 Journal of the Korean Dental Association(대한치과의사협회지), Vol.59(10) : 550-565, 2021-08 
Journal Title
Journal of the Korean Dental Association(대한치과의사협회지)
ISSN
 0376-4672 
Issue Date
2021-08
Keywords
Radiation Protection ; Radiation Dosage ; Radiography ; Dental Radiography ; Panoramic
Abstract
Objective : The objective of this study was to suggest the diagnostic reference levels for intraoral and panoramic radiography through the nationwide survey at regular intervals in South Korea. Study Design : One hundred twenty-six dental institutions from all regions of South Korea were visited. Information on radiographic equipment and clinical exposure parameter was recorded at 118 intraoral and 125 panoramic equipment. Patient entrance dose (PED) and dose-area product (DAP) in intraoral radiography and DAP in panoramic radiography were measured using a DAP meter. Results : Third quartile PED and DAP of intraoral radiography in adults were 1.5 mGy and 46.0 mGy cm2 , those in 12-year-old children 1.2 mGy and 37.1 mGy cm2 and those in 6-year-old children 1.0 mGy and 29.9 mGy cm2 . Third quartile DAP of panoramic radiography in adults, 12, and 6-year-old children were 227 mGy cm2 , 175 mGy cm2 , 163 mGy cm2 , respectively. The median exposure parameters of intraoral radiography in adults were 60kV, 6mA, and 0.23 seconds and those in 12-year-old children 60kV, 6mA, and 0.16 seconds and those in 6-year-old children 60kV, 6mA, and 0.15 seconds. The median exposure parameters of panoramic radiography in adults were 74kV, 10mA, and 13.6 seconds and those in 12-yearold children 67kV, 10mA, and 13.2 seconds and those in 6-year-old children 67kV, 8mA, and 12.0 seconds. Conclusion : As the national DRLs for intraoral radiography and panoramic radiography in Korea, we recommended 1.5 mGy and 227 mGy cm2 for adults, 1.2 mGy and 175 mGy cm2 for 12-year-old children, and 1.0 mGy and 163 mGy cm2 for 6-year-old children, respectively
Files in This Item:
T202125312.pdf Download
DOI
10.22974/jkda.2021.59.10.002
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Oral and Maxillofacial Radiology (영상치의학교실) > 1. Journal Papers
Yonsei Authors
Jeon, Kug Jin(전국진) ORCID logo https://orcid.org/0000-0002-5862-2975
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/187788
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links