atrial fibrillation ; catheter ablation ; duration (time) ; efficacy and safety ; power ; radiofrequency
Abstract
Introduction: Whereas, high-power short-duration (HPSD) radiofrequency (RF) ablation is generally used in atrial fibrillation (AF) catheter ablation (CA), its efficacy, safety, and influence on autonomic function have not been well established in a large population. This study compared HPSD-AFCA and conventional power (ConvP)-AFCA in propensity score matched-population. Methods: In 3,045 consecutive patients who underwent AFCA, this study included 1,260 patients (73.9% male, 59 ± 10 years old, 58.2% paroxysmal type) after propensity score matching: 315 in 50~60W HPSD group vs. 945 in the ConvP group. This study investigated the procedural factors, complication rate, rhythm status, and 3-month heart rate variability (HRV) between the two groups and subgroups. Results: Procedure time was considerably short in the HPSD group (135 min in HPSD vs. 181 min in ConvP, p < 0.001) compared to ConvP group, but there was no significant difference in the complication rate (2.9% in HPSD vs. 3.7% in ConvP, p = 0.477) and the 3-month HRV between the two groups. At the one-year follow-up, there was no significant difference in rhythm outcomes between the two groups (Overall, Log-rank p = 0.885; anti-arrhythmic drug free, Log-rank p = 0.673). These efficacy and safety outcomes were consistently similar irrespective of the AF type or ablation lesion set. The Cox regression analysis showed that the left atrium volume index estimated by computed tomography (HR 1.01 [1.00-1.02]), p = 0.003) and extra-pulmonary vein triggers (HR 1.59 [1.03-2.44], p = 0.036) were independently associated with one-year clinical recurrence, whereas the HPSD ablation was not (HR 1.03 [0.73-1.44], p = 0.887). Conclusion: HPSD-AFCA notably reduced the procedure time with similar rhythm outcomes, complication rate, and influence on autonomic function as ConvP-AFCA, irrespective of the AF type or ablation lesion set.
Files in This Item:
T202124818.pdf Download
DOI
10.3389/fcvm.2021.709585
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Min(김민) ORCID logo https://orcid.org/0000-0002-8132-9873
Kim, Tae-Hoon(김태훈) ORCID logo https://orcid.org/0000-0003-4200-3456
Park, Je Wook(박제욱)
Pak, Hui Nam(박희남) ORCID logo https://orcid.org/0000-0002-3256-3620
Uhm, Jae Sun(엄재선) ORCID logo https://orcid.org/0000-0002-1611-8172
Yu, Hee Tae(유희태) ORCID logo https://orcid.org/0000-0002-6835-4759
Lee, Moon-Hyoung(이문형) ORCID logo https://orcid.org/0000-0002-7268-0741
Joung, Bo Young(정보영) ORCID logo https://orcid.org/0000-0001-9036-7225
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/187529
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links