Volume Percentage of Filling Voids in Root Canals Prepared by a Novel Nickel-Titanium Rotary System (TruNatomy) Using Two Different Obturation Techniques

DC Field Value Language
dc.contributor.author김선일-
dc.contributor.author신수정-
dc.date.accessioned2021-09-29T01:40:09Z-
dc.date.available2021-09-29T01:40:09Z-
dc.date.issued2021-07-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/184488-
dc.description.abstractThis study aimed to compare the volume percentage of filling voids in root canals prepared with a newly introduced rotary system, TruNatomy (Dentsply Maillefer), and obturated by the modified continuous wave (CW) or single cone (SC) filling technique. Plastic tooth models with four canals were enlarged by using TruNatomy files and randomly allocated into either the CW or SC group. The volume percentage of filling voids at 1-6 mm from the apex was analyzed by using microcomputed tomography; mean values were compared by using independent two-sample t-tests (p < 0.05). The mean volume percentages of the filling voids were 2.81 ± 1.11% and 1.77 ± 0.82% in the CW and SC groups, respectively. In the apical area (1-4 mm), volume percentages in the palatal were significantly different between the CW and SC groups; in the middle area (4-6 mm), volume percentages in the palatal and the second mesiobuccal canals were significantly different (p < 0.05). The SC group showed lower volume percentages of filling voids than the CW group. The canals prepared by the TruNatomy system can be obturated well by both the SC and CW techniques. The SC technique showed a lower number of voids, especially in the palatal canals.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMDPI-
dc.relation.isPartOfMATERIALS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleVolume Percentage of Filling Voids in Root Canals Prepared by a Novel Nickel-Titanium Rotary System (TruNatomy) Using Two Different Obturation Techniques-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학교실)-
dc.contributor.googleauthorYou Jin Lee-
dc.contributor.googleauthorSunil Kim-
dc.contributor.googleauthorSu-Jung Shin-
dc.identifier.doi10.3390/ma14143846-
dc.contributor.localIdA00556-
dc.contributor.localIdA02117-
dc.relation.journalcodeJ02182-
dc.identifier.eissn1996-1944-
dc.identifier.pmid34300765-
dc.subject.keywordMicroCT-
dc.subject.keywordTruNatomy-
dc.subject.keywordobturation-
dc.subject.keywordvoids-
dc.contributor.alternativeNameKim, Sun Il-
dc.contributor.affiliatedAuthor김선일-
dc.contributor.affiliatedAuthor신수정-
dc.citation.volume14-
dc.citation.number14-
dc.citation.startPage3846-
dc.identifier.bibliographicCitationMATERIALS, Vol.14(14) : 3846, 2021-07-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.