519 414

Cited 6 times in

Prediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery

DC Field Value Language
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author전익현-
dc.contributor.author김응권-
dc.date.accessioned2021-09-29T01:06:23Z-
dc.date.available2021-09-29T01:06:23Z-
dc.date.issued2021-06-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/184199-
dc.description.abstractThis study evaluated the accuracy of total keratometry (TK) and standard keratometry (K) for intraocular lens (IOL) power calculation in eyes treated with femtosecond laser-assisted cataract surgery. The retrospective study included a retrospective analysis of data from 62 patients (91 eyes) who underwent uneventful femtosecond laser-assisted cataract surgery with Artis PL E (Cristalens Industrie, Lannion, France) IOL implantation by a single surgeon between May 2020 and December 2020 in Severance Hospital, Seoul, South Korea. The new IOLMaster 700 biometry device (Carl Zeiss Meditec, Jena, Germany) was used to calculate TK and K. The mean absolute error (MAE), median absolute error (MedAE), and the percentages of eyes within prediction errors of ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated for all IOL formulas (SRK/T, Hoffer-Q, Haigis, Holladay 1, Holladay 2, and Barrett Universal II). There was strong agreement between K and TK (intraclass correlation coefficient = 0.99), with a mean difference of 0.04 D. For all formulas, MAE tended to be lower for TK than for K, and relatively lower MAE and MedAE values were observed for SRK/T and Holladay 1. Furthermore, for all formulas, a greater proportion of eyes fell within ± 0.25 D of the predicted postoperative spherical equivalent range in the TK group than in the K group. However, differences in MAEs, MedAEs, and percentages of eyes within the above prediction errors were not statistically significant. In conclusion, TK and K exhibit comparable performance for refractive prediction in eyes undergoing femtosecond laser-assisted cataract surgery.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherNature Publishing Group-
dc.relation.isPartOfSCIENTIFIC REPORTS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titlePrediction accuracy of conventional and total keratometry for intraocular lens power calculation in femtosecond laser-assisted cataract surgery-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthorSoyoung Ryu-
dc.contributor.googleauthorIkhyun Jun-
dc.contributor.googleauthorTae-Im Kim-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorEung Kweon Kim-
dc.identifier.doi10.1038/s41598-021-92354-1-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03541-
dc.relation.journalcodeJ02646-
dc.identifier.eissn2045-2322-
dc.identifier.pmid34145357-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.affiliatedAuthor김태임-
dc.contributor.affiliatedAuthor서경률-
dc.contributor.affiliatedAuthor전익현-
dc.citation.volume11-
dc.citation.number1-
dc.citation.startPage12869-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, Vol.11(1) : 12869, 2021-06-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.