145 377

Cited 0 times in

Comparison of Durable-Polymer- and Biodegradable-Polymer-Based Newer-Generation Drug-Eluting Stents in Patients with Acute Myocardial Infarction and Prediabetes After Successful Percutaneous Coronary Intervention

Authors
 Yong Hoon Kim  ;  Ae-Young Her  ;  Myung Ho Jeong  ;  Byeong-Keuk Kim  ;  Sung-Jin Hong  ;  Seunghwan Kim  ;  Chul-Min Ahn  ;  Jung-Sun Kim  ;  Young-Guk Ko  ;  Donghoon Choi  ;  Myeong-Ki Hong  ;  Yangsoo Jang 
Citation
 INTERNATIONAL HEART JOURNAL, Vol.61(4) : 673-684, 2020-07 
Journal Title
INTERNATIONAL HEART JOURNAL
ISSN
 1349-2365 
Issue Date
2020-07
MeSH
Absorbable Implants / statistics & numerical data* ; Aged ; Antineoplastic Agents / administration & dosage ; Drug-Eluting Stents / statistics & numerical data* ; Everolimus / administration & dosage ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Myocardial Infarction / complications ; Myocardial Infarction / surgery* ; Percutaneous Coronary Intervention / instrumentation* ; Prediabetic State / complications* ; Sirolimus / administration & dosage ; Sirolimus / analogs & derivatives
Keywords
Biolimus-eluting stents ; Everolimus-eluting stents ; Zotarolimus-eluting stent
Abstract
Hyperglycemia is an important risk factor for poor clinical outcomes in patients with acute myocardial infarction (AMI). The relative superiority of the long-term clinical outcomes of durable-polymer (DP) -based and biodegradable-polymer (BP) -based newer-generation drug-eluting stents (DESs) after successful percutaneous coronary intervention (PCI) in patients with AMI and prediabetes is not well established. We compared the clinical outcomes in such patients between DP-based and BP-based newer-generation DESs.A total of 4,377 patients with AMI and prediabetes were divided into the following two groups: the DP-DES group (n = 3,775; zotarolimus-eluting stents [ZES; n = 1,546] and everolimus-eluting stents [EES; n = 2,229]) and the BP-DES group (n = 602; biolimus-eluting stents [BES]). The primary endpoint was the occurrence of major adverse cardiac events (MACEs), defined as all-cause death, recurrent myocardial infarction (re-MI), or any repeat revascularization. The secondary endpoint was the occurrence of stent thrombosis (ST).The 2-year adjusted hazard ratio (aHR) of MACEs for ZES versus EES, ZES versus BES, EES versus BES, and ZES/EES versus BES (aHR: 1.125; 95% confidence interval [CI], 0.834-1.518; P = 0.440) were similar. The cumulative incidence of ST was also comparable between the DP-DES and BP-DES groups (aHR: 1.407; 95% CI, 0.476-4.158; P = 0.537). Moreover, the 2-year aHRs of all-cause death, CD, re-MI, target lesion revascularization (TLR), target vessel revascularization (TVR), and non-TVR were similar.Patients with AMI and prediabetes who received DP-DES or BP-DES during PCI showed comparable safety and efficacy during the 2-year follow-up period.
Files in This Item:
T202007125.pdf Download
DOI
10.1536/ihj.19-654
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Ahn, Chul-Min(안철민) ORCID logo https://orcid.org/0000-0002-7071-4370
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
Hong, Sung Jin(홍성진) ORCID logo https://orcid.org/0000-0003-4893-039X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/183829
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links