혈소판감소증 환자에서 혈소판 항체 검출을 위한 Modified Antigen Capture ELISA 방법의 적용 - Thrombomatch EIA, Flow cytometry 검사 방 법과의 비교 -

Other Titles
 Detection of Platelet Antibodies in the Thrombocytopenic Patients by Modified Antigen Capture ELISA : A Comparative Study with Thrombomatch EIA and Flow Cytometry 
Authors
 김인옥  ;  이환섭  ;  김문정  ;  조성란  ;  이정운  ;  남정현  ;  김휘준 
Citation
 Korean Journal of Hematology (대한혈액학회지), Vol.31(3) : 373-381, 1996-12 
Journal Title
Korean Journal of Hematology(대한혈액학회지)
ISSN
 1225-0546 
Issue Date
1996-12
Keywords
Modified antigen capture ELISA ; Antiplatelet antibodies ; Anti-GP Ⅱb/Ⅲa ; Anti-GP Ib/IX
Abstract
Background : There have been several recent reports on autoantibodies to glycoprotein(GP) Ⅱb/Ⅲa and GP Ib/IX, but there are few reports in Korea. In this study, antiplatelet antibodies against anti-GP Ⅱb/Ⅲa and anti-GP Ib/IX were assayed by using a modified antigen capture ELISA(MACE) in 63 patients with thrombocytopenia.
Methods : We studied sera obtained between February, 1994 and July, 1995 from 63 patients with thrombocytopenia. Three Methods were performed for the detection of platelet antibodies, ie. MACE, immunofluorescent assay using flow cytometry, and enzyme immunoassay using Thrombomatch EIA test kit(Biotest AG, Germany).
Results : Thrombomatch EIA test detected all anti-PIAI in the seven sera confirmed by MACE. The detection rate was 32% by MACE, 30% by Thrombomatch EIA, and 14% by flow cytometry in sera collected from the 63 patients with thrombocytopenia. Among 63 thrombocytopenic patients, 5 had anti-GP Ⅱb/Ⅲa ; 4 had anti-GP Ib/IX ; and 11 had both. The concordance rate was 70% between MACE and thrombomatch EIA.
Conclusion : All three Methods have their advantages and disadvantages. MACE identified the glycoprotein specific antibodies, but the method was too complex to routinely use. Thrombomatch EIA is simple to use, but nonspecific reactions were noted. The detection rate of flow cytometry was the lowest among three Methods, but this method appears to more useful for the analysis of platelets than sera. Our Results suggest that none of the three Methods is sufficient to stand alone and that they should be used together in the analysis of platelet antibodies.
Files in This Item:
T199602222.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Hyun Ok(김현옥) ORCID logo https://orcid.org/0000-0002-4964-1963
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/183607
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links