193 312

Cited 0 times in

확장성 심근증환자에서 123I-metaiodobenzylguanidine(MIBG) 심근 스켄 소견 및 심근 MIBG 흡수 정도와 심초음파 지수와의 연관성

Other Titles
 Iodine-123-Metaiodobenzylguanidine Myocardial Scintigraphy in Patients with Dilated Cardiomyopathy : Correlation between Myocardial MIBG Uptake and Echocardiographic Parameters 
Authors
 하종원  ;  이종두  ;  정남식  ;  장양수  ;  김병수  ;  권 준  ;  이문형  ;  차동훈  ;  이영준  ;  심원흠  ;  조승연  ;  김성순 
Citation
 Korean Circulation Journal (순환기), Vol.26(3) : 651-666, 1996-06 
Journal Title
KOREAN CIRCULATION JOURNAL(순환기)
ISSN
 1738-5520 
Issue Date
1996-06
Keywords
Iodine-123-Metaiodobenzylguanidine ; Dilated cardiomyopathy
Abstract
Background: The prognosis of patients with dilated cardiomyopathy remains poor. Doppler echocardiography and cardiac iodine-123-metaiodobenzylguanidine(MIBG) myocardial scintigraphy are useful non-invasive diagnostic modalities to assess the prognosis in these patients. However, the relationship between myocardial MIBG uptake and Doppler echocardiographic. variables was not well investigated. We analyzed the cardiac MIBG imaging in 40 patients with dilated cardiomyopathy and assessed the correlation between the echocardiographic parameters and myocardial MIBG uptake. MIBG uptake(DHM), assessed as the heart/mediastinum ratio measured on anterior view image obtained 4 hours after injection, was compared with M-mode(left ventricular end-diastolic dimension, left ventricular ejection fraction) and Doppler parameters.

Results:
1) Early and delayed MIBG uptake of heart were significantly lower in patient group compared with normal control subjects. There were no significant differences in lung and mediastinum uptake of MIBG between the two groups.

2) Early and delayed MIBG uptake ratios of the heart to lung and heart to mediastinum were significantly lower in patient group compared with those of normal control subjects.

3) DHM was significantly lower in patients with NYHA functional class 3, 4 than those with NYHA functional class 1, 2 in patient group. There was, however, no significant difference of DHM in patient group divided by the degree of mitral regurgitation and left ventricular diastolic filling pattern.

4) There were no significant correlations between DHM and other prognostic factors(left ventricular end-diastolic dimension, left ventricular ejection fraction, peak velocity of early diastolic filling(E velocity), deceleration time of E wave, cardiac output, pulmonary capillary wedge pressure, left ventricular end-diastolic pressure and 24hr urine norepinephrine).

Conclusion: Iodine-123-MIBG scan is a useful noninvasive imaging modality in the assessment of cardiac sympathetic neuronal integrity in patients with dilated cardiomyopathy. There were no significant correlations between cardiac MIBG uptake and other prognostic factors. The cardiac MIBG uptake probably can be utilized as an independent prognostic factor, hence it would be suggested that a large prospective clinical study is needed to consolidate these findings.
Files in This Item:
T199601674.pdf Download
DOI
10.4070/kcj.1996.26.3.651
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sung Soon(김성순)
Shim, Won Heum(심원흠)
Lee, Moon-Hyoung(이문형) ORCID logo https://orcid.org/0000-0002-7268-0741
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Cho, Seung Yun(조승연)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/183417
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links