169 273

Cited 0 times in

Long Lesion의 관상동맥협착에서 Coronary Less Shortening Wallstent : Immediate Result-

Other Titles
 coronary Less Shortening Wallstent in the Long Lesion of Coronary Disease : Immediate Results 
Authors
 장양수  ;  이승환  ;  김종현  ;  하종원  ;  정남식  ;  심원흠  ;  조승연  ;  조홍근 
Citation
 Korean Circulation Journal (순환기), Vol.26(5) : 948-955, 1996-10 
Journal Title
KOREAN CIRCULATION JOURNAL(순환기)
ISSN
 1738-5520 
Issue Date
1996-10
Abstract
Background: Although the first coronary Wallstent implantation ushered in a new era in interventional cordiology with the purpose of circumventing the two major limitations of coronary balloon angioplasty, early acute occlusion and late restenosis, the previous investigators have reported a high rate of subacute occlusion after Wallstent implantation. However, recent studies have reported a low incidence rate of subacute closure and restenosis using the newly modified coronary Less Shortening in aortocoronary vein grafts. The present study reports the immediate results of the Less Shortening Wallstent Implantation for 21 diffuse native coronary lesions in 20 patients.

Methods: Twenty patients were enrolled at the Yonsei Univ. Cardiovasular Center of medical College, Yonsei University in Seoul, Korea from March 1996 through May 1996. The specific angiographic criteria for enrollment included at least 75% diameter stenosis, according to the estimate of two investigatior ; a lesion that was 20mm or more in lenght and a vessel diameter of at least 2.5mm. Bail-out procedure was performed in the case of abrupt closure or threatened closure, defined as a dissection and over 50% residual stenosis of the artery.

Results: The coronary Less Shortening Wallstents were successfully implanted in the 21 diffuse coronary lesions(more than 20mm in length) of the 20 patients(pts), including 7 pts of acute myocardial infarction, 11 pts of unstable angina, and 2 pts of stable angina. Angiographic results after Less Shortening Wallstent were 3.0±0.3mm in minimal luminal diameter(MLD), 6.7±10.8% diameter stenosis(DS) comparing with pre-stent implantation MLD and DS, respectively, 0.3±0.4mm and 89.9±8.4%. During the in-hospital phase, no major cardiac event occurred except 2 cases of transmural myocardial infarction, including one of stent thrombosis and one of side branch occlusion, despite of inclusion of 7 cases of threatened occlusion in the long lesion. The peristent spasms were observed in 11 among 21 lesions, although long term significance of peristent spasm is not defined. The relative risk for peristent spasm were 10 times higher when larger stents(expanded stent diameter/reference artery diameter>1.7) were implanted. There was no peristent spasm when stents of which expanded stent diameter 1.4 times smaller than reference artery size ware used.

Conclusion: The results of this introductory study suggest that new Less Shortening Wallstent may reduce the requirement of multiple stent in the long lesion and a lower rate of thrombotic occusion in comparison to its prototype. Further large scale long term follow-up study is needed to evaluate the role of new Less Shortening Wallstent.
Files in This Item:
T199601462.pdf Download
DOI
10.4070/kcj.1996.26.5.948
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Shim, Won Heum(심원흠)
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Chung, Nam Sik(정남식)
Ha, Jong Won(하종원) ORCID logo https://orcid.org/0000-0002-8260-2958
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/183361
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links