200 317

Cited 0 times in

Region- and voxel-based quantification in human brain of [ 18 F]LSN3316612, a radioligand for O-GlcNAcase

Authors
 Jae-Hoon Lee  ;  Mattia Veronese  ;  Jeih-San Liow  ;  Cheryl L Morse  ;  Jose A Montero Santamaria  ;  Mohammad B Haskali  ;  Sami S Zoghbi  ;  Victor W Pike  ;  Robert B Innis  ;  Paolo Zanotti-Fregonara 
Citation
 EJNMMI RESEARCH, Vol.11(1) : 35, 2021-03 
Journal Title
EJNMMI RESEARCH
Issue Date
2021-03
MeSH
O-GlcNAcase ; Parametric image ; Positron emission tomography ; Tau ; [18F]LSN3316612
Abstract
Background: Previous studies found that the positron emission tomography (PET) radioligand [18F]LSN3316612 accurately quantified O-GlcNAcase in human brain using a two-tissue compartment model (2TCM). This study sought to assess kinetic model(s) as an alternative to 2TCM for quantifying [18F]LSN3316612 binding, particularly in order to generate good-quality parametric images.

Methods: The current study reanalyzed data from a previous study of 10 healthy volunteers who underwent both test and retest PET scans with [18F]LSN3316612. Kinetic analysis was performed at the region level with 2TCM using 120-min PET data and arterial input function, which was considered as the gold standard. Quantification was then obtained at both the region and voxel levels using Logan plot, Ichise's multilinear analysis-1 (MA1), standard spectral analysis (SA), and impulse response function at 120 min (IRF120). To avoid arterial sampling, a noninvasive relative quantification (standardized uptake value ratio (SUVR)) was also tested using the corpus callosum as a pseudo-reference region. Venous samples were also assessed to see whether they could substitute for arterial ones.

Results: Logan and MA1 generated parametric images of good visual quality and their total distribution volume (VT) values at both the region and voxel levels were strongly correlated with 2TCM-derived VT (r = 0.96-0.99) and showed little bias (up to - 8%). SA was more weakly correlated to 2TCM-derived VT (r = 0.93-0.98) and was more biased (~ 16%). IRF120 showed a strong correlation with 2TCM-derived VT (r = 0.96) but generated noisier parametric images. All techniques were comparable to 2TCM in terms of test-retest variability and reliability except IRF120, which gave significantly worse results. Noninvasive SUVR values were not correlated with 2TCM-derived VT, and arteriovenous equilibrium was never reached.

Conclusions: Compared to SA and IRF, Logan and MA1 are more suitable alternatives to 2TCM for quantifying [18F]LSN3316612 and generating good-quality parametric images.
Files in This Item:
T202101593.pdf Download
DOI
10.1186/s13550-021-00780-z
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers
Yonsei Authors
Lee, Jae Hoon(이재훈) ORCID logo https://orcid.org/0000-0002-9898-9886
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/182932
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links