157 357

Cited 0 times in

Fracture strength analysis of titanium insert-reinforced zirconia abutments according to the axial height of the titanium insert with an internal connection

DC Field Value Language
dc.contributor.author정복영-
dc.date.accessioned2021-05-26T16:52:13Z-
dc.date.available2021-05-26T16:52:13Z-
dc.date.issued2021-04-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/182873-
dc.description.abstractThis study aimed to analyze fracture strength in vitro by varying the axial height of the titanium insert and the labial height of the zirconia abutment in an internal connection implant to identify the titanium insert axial height with optimal mechanical stability. Sixty implants with an internal connection system were used. Two-piece zirconia abutments were used with the titanium inserts. Combinations of different titanium insert axial heights (mm) and zirconia abutment labial heights (mm) constituted five groups: Gr1 (1-3), Gr2 (3-3), Gr3 (3-5), Gr4 (5-3), and Gr5 (5-5). After thermocycling, a fracture load test was performed with a universal testing machine. The initial deformation load and the fracture load were measured and analyzed. The fractured surface and cross-section of the specimens were examined by scanning electron microscopy (SEM). The groups of titanium inserts with axial heights of 3 mm and 5 mm showed significantly greater initial deformation load and fracture load than the group with an axial height of 1 mm (p < 0.05), but there was no significant difference between the two groups with axial heights of 3 mm and 5 mm. The labial height of the zirconia abutment had no significant influence on the initial deformation load and fracture load. In some specimens in Gr4 and Gr5, cracking or bending of the titanium insert and abutment screw was observed on SEM. The axial height of the titanium insert should be designed to not be less than 3 mm to increase the fracture strength and promote the long-term stability of implants.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherPublic Library of Science-
dc.relation.isPartOfPLOS ONE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleFracture strength analysis of titanium insert-reinforced zirconia abutments according to the axial height of the titanium insert with an internal connection-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Advanced General Dentistry (통합치의학과)-
dc.contributor.googleauthorSeung-Rye Song-
dc.contributor.googleauthorKyeong-Mee Park-
dc.contributor.googleauthorBock-Young Jung-
dc.identifier.doi10.1371/journal.pone.0249208-
dc.contributor.localIdA03610-
dc.relation.journalcodeJ02540-
dc.identifier.eissn1932-6203-
dc.identifier.pmid33793622-
dc.contributor.alternativeNameJung, Bok Yeong-
dc.contributor.affiliatedAuthor정복영-
dc.citation.volume16-
dc.citation.number4-
dc.citation.startPagee0249208-
dc.identifier.bibliographicCitationPLOS ONE, Vol.16(4) : e0249208, 2021-04-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Advanced General Dentistry (통합치의학과) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.