0 618

Cited 27 times in

Cited 0 times in

Subxiphoid approach for robotic single-site-assisted thymectomy

Authors
 Park, Seong Yong  ;  Han, Kook Nam  ;  Hong, Jeong In  ;  Kim, Hyun Koo  ;  Kim, Dae Joon  ;  Choi, Young Ho 
Citation
 EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, Vol.58(Suppl.1) : 34-38, 2020-08 
Journal Title
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
ISSN
 1010-7940 
Issue Date
2020-08
Keywords
Thymectomy ; Robotic single site ; Subxiphoid approach
Abstract
OBJECTIVES: We previously reported a transthoracic approach using the da Vinci Single-Site (TM) platform. This study describes the outcomes of robotic single-site thymectomy via a subxiphoid approach based on our previous experiences. METHODS: This study included patients, who underwent single-site robotic thymectomy via the subxiphoid approach between September 2018 and October 2019. A 3- to 4-cm vertical incision was made over the subxiphoid area, and the Lapsingle port with CO2 gas was introduced. After docking at the single site, a 5-mm curved cannula, 5-mm cardiere grasper and Maryland bipolar forceps or permanent cautery hook was inserted. The single-site robotic platform was used to conduct all surgical procedures except the dissection around the inferior portion of the thymic tissue performed via a thoracoscopic approach through the same incision. RESULTS: Overall, 13 patients, including 2 with myasthenia gravis, were enrolled. The mean duration of the surgery and chest drainage were 167.3 +/- 52.8 (range 73-253) min and 2.2 +/- 0.9 (range 1-5) days, respectively. All surgeries were successfully completed without conversion to an open surgery, and there were no major post-surgical complications. The diagnoses based on histopathology included thymoma in 10 patients, thymolipoma in 2 patients and atypical carcinoid tumour in 1 patient with free resection margin. CONCLUSIONS: This study demonstrated that robotic single-site-assisted thymectomy via the subxiphoid approach is a safe and technically feasible procedure. Although this initial series comprised relatively simple cases, more advanced and complex procedures can soon be performed with the advent of single-port robotic platform.
DOI
10.1093/ejcts/ezaa036
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Dae Joon(김대준)
Park, Seong Yong(박성용) ORCID logo https://orcid.org/0000-0002-5180-3853
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/182695
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links