Tissue surface adaptation of CAD-CAM maxillary and mandibular complete denture bases manufactured by digital light processing: A clinical study

Authors
 Yoon, Se-Na  ;  Oh, Kyung Chul  ;  Lee, Sang J.  ;  Han, Jung-Suk  ;  Yoon, Hyung-In 
Citation
 JOURNAL OF PROSTHETIC DENTISTRY, Vol.124(6) : 682-689, 2020-12 
Journal Title
JOURNAL OF PROSTHETIC DENTISTRY
ISSN
 0022-3913 
Issue Date
2020-12
Abstract
Statement of problem. Clinical studies evaluating the tissue surface adaptation of complete denture bases fabricated by digital light processing (DLP) are lacking. Purpose. The purpose of this clinical study was to assess the tissue surface adaptation of complete denture bases generated by the DLP technique and to compare the adaptation with that of denture bases manufactured by 5-axis milling (MIL) and pack-and-press (PAP) method. Material and methods. A total of 9 participants with 12 edentulous arches (7 maxillary and 5 mandibular) were included in this study. For each edentulous arch, the complete denture bases with occlusion rims were prepared by 3 different techniques (PAP, MIL, and DLP). A virtual denture base with occlusion rim was designed by means of a digital subtraction tool and served to fabricate the DLP and MIL denture bases. The complete denture bases were placed intraorally with an indicator applied to the intaglio surfaces. The thickness of the indicator was measured within the denture-bearing areas and anatomic landmarks of the edentulous arch to obtain the absolute tissue surface adaptation (ATA) value. The relative tissue surface adaptation (RTA) value was calculated from the differences between the ATA values of DLP or MIL techniques and those of the PAP technique. The Kruskal-Wallis test and the McNemar test were used for statistical analysis (alpha=.05). Results. No statistically significant differences were found among the 3 denture base fabrication techniques with respect to the ATA values of either arch (P<.05). The DLP base exhibited a higher frequency of negative RTA values than the MIL base. Regarding the RTA values for the mandibular arch, no significant differences were detected between the DLP and MIL denture bases (P>.05). Conclusions. The DLP and MIL denture bases demonstrated clinically acceptable tissue surface adaptation to both edentulous the maxilla and mandible. The DLP denture base was likely to exhibit intimate tissue adaptation in the stress-bearing areas of maxillary arches compared with the PAP denture base. The maxillary MIL denture base was likely to exhibit small gaps between the supporting tissue and denture base. Both DLP and MIL mandibular denture bases were likely to show intimate adaptation on the lingual slope compared with the PAP base.
Full Text
https://www.sciencedirect.com/science/article/pii/S0022391319307383
DOI
10.1016/j.prosdent.2019.11.007
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Oh, Kyung Chul(오경철) ORCID logo https://orcid.org/0000-0003-4584-2597
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/181789
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links