174 497

Cited 7 times in

Effects of Intrabony Length and Cortical Bone Density on the Primary Stability of Orthodontic Miniscrews

DC Field Value Language
dc.contributor.author권재성-
dc.contributor.author최성환-
dc.date.accessioned2021-01-19T07:50:48Z-
dc.date.available2021-01-19T07:50:48Z-
dc.date.issued2020-12-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/181345-
dc.description.abstractMiniscrews have gained recent popularity as temporary anchorage devices in orthodontic treatments, where failure due to sinus perforations or damage to the neighboring roots have increased. Issues regarding miniscrews in insufficient interradicular space must also be resolved. This study aimed to evaluate the primary stability of miniscrews shorter than 6 mm and their feasibility in artificial bone with densities of 30, 40, and 50 pounds per cubic foot (pcf). The primary stability was evaluated by adjusting the intrabony miniscrew length, based on several physical properties: maximum insertion torque (MIT), maximum removal torque (MRT), removal angular momentum (RAM), horizontal resistance, and micromotion. The MIT and micromotion results demonstrated that the intrabony length of a miniscrew significantly affected its stability in low-density cortical bone, unlike cases with a higher cortical bone density (p < 0.05). The horizontal resistance, MRT, and RAM were affected by the intrabony length, regardless of the bone density (p < 0.05). Thus, the primary stability of miniscrews was affected by both the cortical bone density and intrabony length. The effect of the intrabony length was more significant in low-density cortical bone, where the implantation depth increased as more energy was required to remove the miniscrew. This facilitated higher resistance and a lower risk of falling out.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMDPI-
dc.relation.isPartOfMATERIALS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEffects of Intrabony Length and Cortical Bone Density on the Primary Stability of Orthodontic Miniscrews-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실)-
dc.contributor.googleauthorJie Jin-
dc.contributor.googleauthorGi-Tae Kim-
dc.contributor.googleauthorJae-Sung Kwon-
dc.contributor.googleauthorSung-Hwan Choi-
dc.identifier.doi10.3390/ma13245615-
dc.contributor.localIdA00247-
dc.contributor.localIdA04083-
dc.relation.journalcodeJ02182-
dc.identifier.eissn1996-1944-
dc.identifier.pmid33317089-
dc.subject.keywordcortical bone density-
dc.subject.keywordintrabony length-
dc.subject.keywordminiscrew length-
dc.subject.keywordminiscrews-
dc.subject.keywordprimary stability-
dc.subject.keywordremoval angular momentum-
dc.contributor.alternativeNameKwon, Jae-Sung-
dc.contributor.affiliatedAuthor권재성-
dc.contributor.affiliatedAuthor최성환-
dc.citation.volume13-
dc.citation.number24-
dc.citation.startPage5615-
dc.identifier.bibliographicCitationMATERIALS, Vol.13(24) : 5615, 2020-12-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.