dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/180408-
dc.description.abstractThe goal of this study is the preparation of safer coated microneedles so that tips remaining after the initial use are less likely to be reinserted on a second use. Twelve groups of uncoated microneedles (u-MNs) were prepared from the combination of three different aspect ratios (height to base width) and four kinds of polymer (polyethylene (PE), polypropylene (PP), nylon and polylactic acid (PLA)). After coating the u-MNs with polyvinyl alcohol formulation to make coated MNs (c-MNs), the force displacement of the u-MNs and the c-MNs was measured. The aspect ratio was reduced from 2.2, 2.5 and 3.0 with u-MNs to 1.3, 1.4 and 1.6 with c-MNs, respectively, after the coating formulation was applied to the MNs. All PLA MNs had a puncture performance of more than 95%. However, the puncture performance of u-MNs made of PE and of PP with a 3.0 aspect ratio was only 8% and 53%, respectively, whereas the rates of c-MNs made of PE and of PP were 82% and 95%, respectively. In animal experiments with PP MNs with a 3.0 aspect ratio, the 59% rate of puncture performance with u-MNs increased to above 96% with c-MNs and fell to 13% for r-MNs. Safe c-MNs can overcome the disadvantages of standard c-MNs by reducing the probable contamination of remaining tips after use. Safe c-MNs have advantages over standard c-MNs in terms of humidity resistance, reasonable cost, sterilization process and short processing time through the separate process of u-MN preparation and simple dip-coating.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMultidisciplinary Digital Publishing Institute-
dc.relation.isPartOfMICROMACHINES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleSafe Coated Microneedles with Reduced Puncture Occurrence after Administration-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Microbiology (미생물학교실)-
dc.contributor.googleauthorHye-Rin Jeong-
dc.contributor.googleauthorHyesun Jun-
dc.contributor.googleauthorHye-Ran Cha-
dc.contributor.googleauthorJae Myun Lee-
dc.contributor.googleauthorJung-Hwan Park-
dc.identifier.doi10.3390/mi11080710-
dc.contributor.localIdA03071-
dc.relation.journalcodeJ03026-
dc.identifier.eissn2072-666X-
dc.identifier.pmid32707873-
dc.subject.keywordaspect ratio-
dc.subject.keywordcoated microneedles-
dc.subject.keywordmechanical property of polymer-
dc.subject.keywordpuncture performance-
dc.subject.keywordre-administration-
dc.contributor.alternativeNameLee, Jae Myun-
dc.contributor.affiliatedAuthor이재면-
dc.citation.volume11-
dc.citation.number8-
dc.citation.startPage710-
dc.identifier.bibliographicCitationMICROMACHINES, Vol.11(8) : 710, 2020-07-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Microbiology (미생물학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.