415 531

Cited 0 times in

토포라이저 바리오를 이용한 각막굴절력검사의 신뢰도 연구

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author이형근-
dc.contributor.author전익현-
dc.date.accessioned2020-12-01T17:27:46Z-
dc.date.available2020-12-01T17:27:46Z-
dc.date.issued2020-08-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/180280-
dc.description.abstractPurpose: To evaluate the clinical reliability of the Topolyzer Vario (Wavelight-Alcon, Erlangen, Germany), we compared three different corneal topographers in terms of corneal refractive power. Methods: The medical records of patients who visited Severance Hospital for corneal refractive surgery were retrospectively reviewed. Keratometric data of patients who underwent evaluations using the Pentacam HR (Oculus, Wetzlar, Germany), ORBscan II (Bausch & Lomb, Rochester, NY, USA), and Topolyzer Vario instruments on the same day were obtained. Flat keratometry (Kf), steep keratometry (Ks), mean keratometry (Km), astigmatism keratometry (Kastig), Cartesian astigmatism (J0), and oblique astigmatism (J45) values were calculated. The measurement values of the three devices were subjected to Pearson’s correlation analysis and repeated measures analysis of variance (with Bonferroni correction); a Bland-Altman plot was also created. Results: The keratometric data of 80 eyes were included in the analysis and all of the keratometric measurements obtained by the three devices showed significant correlations, i.e., good agreement. The Kf and Km measurements of the Pentacam HR were flatter than those of the ORBscan II, and the Kf, Km, Ks, and J45 measurements were flatter than those of the Topolyzer Vario. However, there was no significant difference in keratometric values between the ORBscan II and Topolyzer Vario. Furthermore, the difference in corneal refractive power between the Pentacam HR and Topolyzer Vario was not clinically significant. Conclusions: When measuring the corneal refractive power of patients without any history of corneal disorder or ocular surgery, the Topolyzer Vario is a clinically reliable device that shows similar performance to the ORBscan II and Pentacam HR.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title토포라이저 바리오를 이용한 각막굴절력검사의 신뢰도 연구-
dc.title.alternativeClinical Reliability of the Topolyzer Vario Instrument for Measurement of Corneal Refractive Power-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthor설동헌-
dc.contributor.googleauthor전익현-
dc.contributor.googleauthor이형근-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2020.61.8.882-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03303-
dc.contributor.localIdA03541-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordCorneal refractive power-
dc.subject.keywordKeratometry-
dc.subject.keywordTopographer-
dc.subject.keywordTopolyzer vario-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.affiliatedAuthor김응권-
dc.contributor.affiliatedAuthor김태임-
dc.contributor.affiliatedAuthor서경률-
dc.contributor.affiliatedAuthor이형근-
dc.contributor.affiliatedAuthor전익현-
dc.citation.volume61-
dc.citation.number8-
dc.citation.startPage882-
dc.citation.endPage889-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.61(8) : 882-889, 2020-08-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.