dc.description.abstractPurpose To evaluate the biomechanical properties of corneas using a dynamic Scheimpflug analyzer (Corvis ST) after penetrating keratoplasty (PKP) and Descemet’s membrane stripping keratoplasty (DSEK). Methods The medical records of 11 eyes that had undergone PKP (PKP group) and 11 eyes that had undergone DSEK (DSEK group) from March 2017 to March 2018 and the results were compared with 20 eyes of the control group. All patients’ corneal biomechanical properties, including a deformation amplitude ratio of 2.0 mm (DA ratio 2.0 mm), integrated inverse radius (IntInvRad), stiffness parameter at first applanation (SP-A1), and Ambrosio relational thickness through the horizon meridian (ARTh) were measured and compared with those of the normal control group. In addition, biomechanically corrected intraocular pressure (bIOP) measured by the Corvis ST was compared with intraocular pressure measured by a Tono-Pen Applanation Tonometer (IOP-Tono-Pen). Results In the PKP group, the biomechanical properties using the Corvis ST showed a significantly lower DA ratio 2.0 mm, SP-A1, ARTh, and IntInvRad, compared with those of the control group. However, in the DSEK group, only ARTh was significantly lower than that of the control group. Conclusions Corvis ST can be used to measure the change of corneal biomechanical properties after corneal transplantation.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title각막이식수술 후 동적 샤임플러그 분석 장비를 이용한 각막의 생역학적 특성 변화-
dc.title.alternativeThe Use of a Dynamic Scheimpflug Analyzer to Measure Changes of Post-keratoplasty Corneal Biomechanical Properties-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthor박서진-
dc.contributor.googleauthor전익현-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2020.61.6.597-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03541-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordCorneal biomechanical properties-
dc.subject.keywordCorvis ST-
dc.subject.keywordDescemet’s membrane stripping keratoplasty-
dc.subject.keywordPenetrating keratoplasty-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.affiliatedAuthor김응권-
dc.contributor.affiliatedAuthor김태임-
dc.contributor.affiliatedAuthor서경률-
dc.contributor.affiliatedAuthor전익현-
dc.citation.volume61-
dc.citation.number6-
dc.citation.startPage597-
dc.citation.endPage602-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.61(6) : 597-602, 2020-06-
dc.identifier.rimsid67292-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.