0 283

Cited 0 times in

Automatic stimulus breaker for electric dental pulp tester using pain response

DC Field Value Language
dc.contributor.author이승종-
dc.date.accessioned2020-09-04T02:14:23Z-
dc.date.available2020-09-04T02:14:23Z-
dc.date.issued2005-06-
dc.identifier.issn0140-0118-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178887-
dc.description.abstractThe pulp test provides a means of examining the vitality of dental pulp using physical or chemical stimulation. During electrical pulp testing, an electrical current stimulates the intradental nerve, which may be painful and stressful to patients. The study involved measurement of the electromyogram (EMG) from the anterior belly of the digastric muscle, finger movement and voice response during electrical pulp testing. The excessive stimulus time from the onset time of response (EMG, voice and finger movement) to the end of the stimulation was obtained. The results indicated that the responses occurred in the order: EMG, finger and voice. Based on these results, an automatic stimulus shut-off circuit was developed using the above-mentioned responses to stimulus during electric pulp testing. Excessive stimulus time was reduced by prompt switching-off of the pulp tester output, 64 ms on average after the first detected response (EMG). Consequently, excessive stimulus times were reduced by 284 and 152 ms on average for the subject and examiner disconnection, respectively, using the developed automatic shut-off circuit. Therefore it was possible to minimise pain and stress by reducing excessive pulp stimulation.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish, French(Summary), German(Summary)-
dc.publisherSpringer-
dc.relation.isPartOfMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAdult-
dc.subject.MESHDental Pulp Test / adverse effects-
dc.subject.MESHDental Pulp Test / methods*-
dc.subject.MESHElectric Stimulation / methods-
dc.subject.MESHElectromyography-
dc.subject.MESHFemale-
dc.subject.MESHFingers / physiology-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMovement-
dc.subject.MESHPain Measurement / methods*-
dc.subject.MESHVoice-
dc.titleAutomatic stimulus breaker for electric dental pulp tester using pain response-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학교실)-
dc.contributor.googleauthorK C Nam-
dc.contributor.googleauthorS J Lee-
dc.contributor.googleauthorC G Song-
dc.contributor.googleauthorD W Kim-
dc.identifier.doi10.1007/BF02345815-
dc.contributor.localIdA02925-
dc.relation.journalcodeJ02195-
dc.identifier.eissn1741-0444-
dc.identifier.pmid16035226-
dc.identifier.urlhttps://link.springer.com/article/10.1007/BF02345815-
dc.contributor.alternativeNameLee, Seung Jong-
dc.contributor.affiliatedAuthor이승종-
dc.citation.volume43-
dc.citation.number3-
dc.citation.startPage375-
dc.citation.endPage378-
dc.identifier.bibliographicCitationMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, Vol.43(3) : 375-378, 2005-06-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.