0 240

Cited 3 times in

An improved approach for measurement of stroke volume during treadmill exercise

DC Field Value Language
dc.contributor.author김덕원-
dc.date.accessioned2020-09-04T02:02:26Z-
dc.date.available2020-09-04T02:02:26Z-
dc.date.issued2003-07-
dc.identifier.issn1350-4533-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178766-
dc.description.abstractIn this study, a new ensemble averaging technique was developed to measure cardiac output during treadmill exercise. Each dz/dt peak is used as a starting point for ensemble averaging, instead of the conventionally used R point of ECG, in order to prevent the peak dz/dt waveform (C point) to be smoothed, which results in increased dz/dtmax. When using the R point as a reference, time interval from the R point to the peak dz/dt varies for each heart beat. Signal to noise ratios (SNR) of the five subjects with the new technique were 12.9, 16. 4, 10.6, 14.0, and 4.6% higher than those with the conventional one at rest and during four levels of exercise, respectively. Power density spectra of the averaged dz/dt waveforms by the peak dz/dt and R point referencing were also analyzed. Stroke volumes of the five subjects averaged by the peak dz/dt were 4.9, 6.8, 7.6, 7.4, and 9.8% higher than those by the R point at rest and during four levels of exercise, respectively.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherButterworth-Heinemann-
dc.relation.isPartOfMEDICAL ENGINEERING & PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAlgorithms*-
dc.subject.MESHArtifacts*-
dc.subject.MESHCardiography, Impedance / instrumentation-
dc.subject.MESHCardiography, Impedance / methods*-
dc.subject.MESHDiagnosis, Computer-Assisted / instrumentation-
dc.subject.MESHDiagnosis, Computer-Assisted / methods*-
dc.subject.MESHExercise Test / instrumentation-
dc.subject.MESHExercise Test / methods*-
dc.subject.MESHHeart Rate / physiology*-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHStroke Volume / physiology*-
dc.titleAn improved approach for measurement of stroke volume during treadmill exercise-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthorC G Song-
dc.contributor.googleauthorD W Kim-
dc.identifier.doi10.1016/s1350-4533(03)00024-9-
dc.contributor.localIdA00376-
dc.relation.journalcodeJ02198-
dc.identifier.eissn1873-4030-
dc.identifier.pmid12787990-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1350453303000249-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.affiliatedAuthor김덕원-
dc.citation.volume25-
dc.citation.number6-
dc.citation.startPage517-
dc.citation.endPage522-
dc.identifier.bibliographicCitationMEDICAL ENGINEERING & PHYSICS, Vol.25(6) : 517-522, 2003-07-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.