dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178546-
dc.description.abstractSince Korea Food and Drug Administration and The Ministry of Health-Welfare published guidelinefor its recommendations on issues related to patient radiation dose from CT X-ray to reduce patientdose in 2009, it has been followed up. As a result of this effort, recently many hospital has been buildingup dose monitoring system to collect and manage radiation dose systematically. In case CT whichis installed and used in hospital does support dose report by structured report, it is easy to providedose report to dose monitoring system. However It is very hard to integrate radiation dose from CT installedor manufactured before DICOM SR requirements containing dose report was released, whichwas defined by DICOM Standard Committee into dose monitoring system so that this makes it difficultto comply with guideline for diagnostic reference level. Therefore this report contains the experienceon integrating the value of DLP (Dose Length product) from CT installed in radiology department ofuniversity hospital of Seoul into dose monitoring system by using Optical Character Recognition technology.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한의학영상정보학회-
dc.relation.isPartOfJournal of the Korean Society of Imaging Informatics in Medicine (대한의학영상정보학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title광학문자인식(OCR)에 의한 CT 방사선 선량 관리시스템 개발에 관한 연구-
dc.title.alternativeThe Study on Radiation Dose Monitoring System Development of Computed Tomography (CT) by Optical Character Recognition (OCR)-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthor윤영욱-
dc.contributor.googleauthor김남현-
dc.contributor.googleauthor백창구-
dc.contributor.localIdA00357-
dc.relation.journalcodeJ01875-
dc.subject.keywordDose monitoring system-
dc.subject.keywordDose report-
dc.subject.keywordDICOM structured report-
dc.subject.keywordDiagnostic reference report-
dc.subject.keywordOptical c-
dc.contributor.alternativeNameKim, Nam Hyun-
dc.contributor.affiliatedAuthor김남현-
dc.citation.volume18-
dc.citation.number1-
dc.citation.startPage27-
dc.citation.endPage31-
dc.identifier.bibliographicCitationJournal of the Korean Society of Imaging Informatics in Medicine (대한의학영상정보학회지), Vol.18(1) : 27-31, 2012-12-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.