Cited 0 times in
만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 정일영 | - |
dc.date.accessioned | 2020-07-03T17:52:26Z | - |
dc.date.available | 2020-07-03T17:52:26Z | - |
dc.date.issued | 1997 | - |
dc.identifier.issn | 1225-0864 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/177900 | - |
dc.description.abstract | The purpose of this study was to compare the effects of various techniques on the quality and quantity of instrumentation in curved canals. Instrumentation time was evaluated too. Forty eight canals of resin blocks($35^{\circ}$ 수식 이미지) were divided into three groups and filed. In group A, 16 blocks were instrumented using a step-back technique with stainless steel(SS) K-file(Mani, Matsutani Seisakusho Co.,Japan). In group B, canals were prepared with SS K-files using the Endo-Angle (Nakanishi Dental MFG.CO.,LTD.,Japan). Group C was prepared using N i-Ti engine-driven instruments (Quantec Series $2000^{TM}$ 수식 이미지 system). Group A and B were filed from # 5 to # 25 at the apex followed by a 1 mm stepback technique, and the coronal half of the canals were flared with Gates Glidden burs(#2,3,4). Group C was instrumented from # 1 to # 8. After the instrumentation time was measured, canals were filled with India ink, and photographed, which to magnify the canal images 8 times. Using these photographs the apical portions were evaluated And scored from 1 to 4 according to the severity of ledging and zipping. On the same photographs, the area of the coronal two thirds of the canals were measured using a personal computer with the computer program Brain and Digitizer (SummaSketch III). The following results were obtained. 1. Instrumentation time was significantly shorter for group C, as opposed to group A and B(ANOVA, P<0.05). 2. The qualitative evaluation of the apical portions of the canals showed no significant difference between the groups(Kruscal-Wallis, p>0.05). 3. The area removed by group C was significantly smaller than group A and B(ANOVA, P<0.05). | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한치과보존학회 | - |
dc.relation.isPartOf | Journal of Korean Academy of Operative Dentistry (대한치과보존학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구 | - |
dc.title.alternative | The EFFECTS OF VARIOUS INSTRUMENTATION TECHNIQUES IN CURVED CANALS OF RESIN BLOCKS | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Conservative Dentistry (보존과학교실) | - |
dc.contributor.googleauthor | 정일영 | - |
dc.contributor.googleauthor | 윤태철 | - |
dc.contributor.googleauthor | 이승종 | - |
dc.contributor.localId | A03700 | - |
dc.relation.journalcode | J01488 | - |
dc.contributor.alternativeName | Jung, Il Young | - |
dc.contributor.affiliatedAuthor | 정일영 | - |
dc.citation.volume | 22 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 648 | - |
dc.citation.endPage | 658 | - |
dc.identifier.bibliographicCitation | Journal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.22(2) : 648-658, 1997 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.