294 393

Cited 14 times in

PET Quantification of Brain O-GlcNAcase With [ F 18 ]LSN3316612 in Healthy Human Volunteers

Authors
 Jae-Hoon Lee  ;  Jeih-San Liow  ;  Soumen Paul  ;  Cheryl L Morse  ;  Mohammad B Haskali  ;  Lester Manly  ;  Sergey Shcherbinin  ;  J Craig Ruble  ;  Nancy Kant  ;  Emily C Collins  ;  Hugh N Nuthall  ;  Paolo Zanotti-Fregonara  ;  Sami S Zoghbi  ;  Victor W Pike  ;  Robert B Innis 
Citation
 EJNMMI RESEARCH, Vol.10 : 20, 2020-03 
Journal Title
EJNMMI RESEARCH
Issue Date
2020-03
Keywords
Neuroimaging ; O-GlcNAcase ; Positron emission tomography ; Tauopathy ; Test-retest reliability
Abstract
Background: Previous studies found that [18F]LSN3316612 was a promising positron emission tomography (PET) radioligand for imaging O-GlcNAcase in nonhuman primates and human volunteers. This study sought to further evaluate the suitability of [18F]LSN3316612 for human clinical research.

Methods: Kinetic evaluation of [18F]LSN3316612 was conducted in a combined set of baseline brain scans from 17 healthy human volunteers and test-retest imaging was conducted in 10 of these volunteers; another 6 volunteers had whole-body scans to measure radiation exposure to body organs. Total distribution volume (VT) estimates were compared for the one- and two-tissue compartment models with the arterial input function. Test-retest variability and reliability were evaluated via mean difference and intraclass correlation coefficient (ICC). The time stability of VT was assessed down to a 30-min scan time. An alternative quantification method for [18F]LSN3316612 binding without blood was also investigated to assess the possibility of eliminating arterial sampling.

Results: Brain uptake was generally high and could be quantified as VT with excellent identifiability using the two-tissue compartment model. [18F]LSN3316612 exhibited good absolute test-retest variability (12.5%), but the arithmetic test-retest variability was far from 0 (11.3%), reflecting a near-uniform increase of VT on the retest scan in nine of 10 volunteers. VT values were stable after 110 min in all brain regions, suggesting that no radiometabolites accumulated in the brain. Measurements obtained using only brain activity (i.e., area under the curve (AUC) from 150-180 min) correlated strongly with regional VT values during test-retest conditions (R2 = 0.84), exhibiting similar reliability to VT (ICC = 0.68 vs. 0.64). Estimated radiation exposure for [18F]LSN3316612 PET was 20.5 ± 2.1 μSv/MBq, comparable to other 18F-labeled radioligands for brain imaging.

Conclusions: [18F]LSN3316612 is an excellent PET radioligand for imaging O-GlcNAcase in the human brain. Alternative quantification without blood is possible, at least for within-subject repeat studies. However, the unexplained increase of VT under retest conditions requires further investigation.
Files in This Item:
T202001667.pdf Download
DOI
10.1186/s13550-020-0616-4
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers
Yonsei Authors
Lee, Jae Hoon(이재훈) ORCID logo https://orcid.org/0000-0002-9898-9886
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/176232
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links