243 513

Cited 3 times in

Comparison of prostate cancer detection rates of various prostate biopsy methods for patients with prostate-specific antigen levels of <10.0 ng/mL in real-world practice

Authors
 Kyung Tak Oh  ;  Kyo Chul Koo  ;  Byung Ha Chung  ;  Kwang Suk Lee 
Citation
 INVESTIGATIVE AND CLINICAL UROLOGY, Vol.61(1) : 28-34, 2020 
Journal Title
INVESTIGATIVE AND CLINICAL UROLOGY
ISSN
 2466-0493 
Issue Date
2020
Keywords
Biopsy ; Image-guided biopsy ; Prostatic neoplasms
Abstract
Purpose:

Several strategies of prostate biopsy (PBx) have been introduced to improve prostate cancer (PCa) detection rates. However, studies comparing cancer detection rates (CDRs) according to biopsy methods in real-world practice are scarce. This study aimed to investigate CDRs according to the biopsy methods for patients with prostate-specific antigen (PSA) <10.0 ng/mL.

Materials and Methods:

From 2006 to 2015, patients who underwent PBx were initially selected. All patients were categorized according to the biopsy methods performed (magnetic resonance imaging targeted biopsy [MR-TBx], 12+2 hypoechoic lesion target biopsy, saturation biopsy [sPBx], extended biopsy, and 12-core PBx). The CDR of MR-TBx was compared to that of sPBx and other protocols. Volume per core (VPC) was defined as prostate volume divided by the number of biopsy cores. Patients previously diagnosed with PCa were excluded.

Results:

Of the 1,598 patients (median PSA, 5.41 ng/mL), 401 (25.1%) were diagnosed with PCa. Among the biopsy methods, MR-TBx has the highest CDR and proportion of Gleason score ≥7 (3+4). Biopsy methods, VPC, age, prostate volume, and PSA were associated with PCa detection. In the sub-analysis for initial biopsy, MR-TBx had no significant difference with sPBx, but had higher CDR than the other biopsy protocols. For repeat biopsy, VPC, rather than the biopsy method, was associated with CDR.

Conclusions:

This study reaffirmed the efficacy of MR-TBx on CDR in real-world practice. In cases with barriers to performing magnetic resonance imaging, VPC might be useful for adjusting the optimal number of biopsy cores in repeat biopsy.
Files in This Item:
T202000173.pdf Download
DOI
10.4111/icu.2020.61.1.28
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Urology (비뇨의학교실) > 1. Journal Papers
Yonsei Authors
Koo, Kyo Chul(구교철) ORCID logo https://orcid.org/0000-0001-7303-6256
Lee, Kwang Suk(이광석) ORCID logo https://orcid.org/0000-0002-7961-8393
Chung, Byung Ha(정병하) ORCID logo https://orcid.org/0000-0001-9817-3660
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/174931
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links