Cited 0 times in
척수손상 환자에서의 진동 및 전기자극을 이용한 사정유도와 정액분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김덕용 | - |
dc.contributor.author | 김용욱 | - |
dc.contributor.author | 박은숙 | - |
dc.contributor.author | 박창일 | - |
dc.contributor.author | 신지철 | - |
dc.contributor.author | 조성래 | - |
dc.date.accessioned | 2020-01-23T05:35:05Z | - |
dc.date.available | 2020-01-23T05:35:05Z | - |
dc.date.issued | 1999 | - |
dc.identifier.issn | 1225-584X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/174391 | - |
dc.description.abstract | Objective : The purposes of this study were to compare the quality of semen obtained by vibratory and electrical stimulation according to the injury level and to investigate the changes of semen by repeated ejaculations in spinal cord injured patients. Method : Seventeen spinal cord injured men had repeated ejaculations at least three times with vibratory (Ferticare®) and electrical stimulation (Seager®) at weekly interval. Results : In patients with lesions above the T10 level, the response rate was 91.7% by the vibratory stimulation and 100.0% by the electrical stimulation. The percentage of adequate sperm quality (total count of motile sperm ≥ 5⁓105) was 81.8% by the vibratory stimulation and 66.7% by the electrical stimulation. In patients with lesions at and below the T10 level, all patients responded to the electrical stimulation, but not to the vibratory stimulation. The percentage of adequate sperm quality was 82.6% by the electrical stimulation. The quality of semen obtained by the vibratory stimulation was better than that of the electrical stimulation (p<0.05). Sperm quality didn't improve through the repeated ejaculations. Conclusion : The vibratory ejaculation may be more effective in obtaining the adequate sperm quality in patients with lesions above the T10 level. However, the electrical stimulation may be more effective in patients with lesions at and below the T10 level. Repeated ejaculations for a short period may be ineffective for a sperm quality improvement. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한재활의학회 | - |
dc.relation.isPartOf | Journal of the Korean Academy of Rehabilitation Medicine (대한재활의학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 척수손상 환자에서의 진동 및 전기자극을 이용한 사정유도와 정액분석 | - |
dc.title.alternative | Ejaculatory Induction with Vibratory and Electrical Stimulation and Semen Analysis in Spinal Cord Injured Patients | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Rehabilitation Medicine (재활의학교실) | - |
dc.contributor.googleauthor | 박창일 | - |
dc.contributor.googleauthor | 신지철 | - |
dc.contributor.googleauthor | 박은숙 | - |
dc.contributor.googleauthor | 김덕용 | - |
dc.contributor.googleauthor | 조성래 | - |
dc.contributor.googleauthor | 김용욱 | - |
dc.contributor.googleauthor | 온석훈 | - |
dc.contributor.localId | A00375 | - |
dc.contributor.localId | A00750 | - |
dc.contributor.localId | A01611 | - |
dc.contributor.localId | A01717 | - |
dc.contributor.localId | A02162 | - |
dc.contributor.localId | A03831 | - |
dc.relation.journalcode | J01803 | - |
dc.subject.keyword | Spinal cord injury | - |
dc.subject.keyword | Fertility | - |
dc.subject.keyword | Ejaculation | - |
dc.subject.keyword | Semen analysis | - |
dc.contributor.alternativeName | Kim, Deog Young | - |
dc.contributor.affiliatedAuthor | 김덕용 | - |
dc.contributor.affiliatedAuthor | 김용욱 | - |
dc.contributor.affiliatedAuthor | 박은숙 | - |
dc.contributor.affiliatedAuthor | 박창일 | - |
dc.contributor.affiliatedAuthor | 신지철 | - |
dc.contributor.affiliatedAuthor | 조성래 | - |
dc.citation.volume | 23 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 777 | - |
dc.citation.endPage | 785 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Academy of Rehabilitation Medicine (대한재활의학회지), Vol.23(4) : 777-785, 1999 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.