0 350

Cited 6 times in

Measurement of leg arterial compliance of normal subjects and diabetics using impedance plethysmography

DC Field Value Language
dc.contributor.author김덕원-
dc.date.accessioned2020-01-23T05:33:35Z-
dc.date.available2020-01-23T05:33:35Z-
dc.date.issued1999-
dc.identifier.issn0077-8923-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/174374-
dc.description.abstractIn this study, compliance, a mechanical characteristic of the lower leg arteries, was measured noninvasively. Changes in blood volume and pressure were measured using impedance plethysmography and a mercury sphygmomanometer, respectively. Compliance was calculated by dividing the change in blood volume by the change in pulse pressure (systolic-diastolic pressure). Subjects were 24 asymptomatic persons ranging from 30 to 58 years and 14 diabetics ranging from 41 to 59 years. Peak compliance, mean pressure, and systolic pressure were statistically analyzed using a t test between the asymptomatic and diabetic groups. The average peak compliance of the asymptomatic and diabetic groups was measured as 2.79 and 1.82 microL/mmHg/cm, respectively, and these were significantly different (p < 0.01). It was also found that compliance is a better parameter in differentiating vascular disease than the mean or systolic blood pressure.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherBlackwell-
dc.relation.isPartOfAnnals of the New York Academy of Sciences-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAdult-
dc.subject.MESHAge Factors-
dc.subject.MESHBlood Pressure-
dc.subject.MESHBlood Volume-
dc.subject.MESHCompliance-
dc.subject.MESHDiabetic Angiopathies/diagnosis*-
dc.subject.MESHHumans-
dc.subject.MESHLeg/blood supply*-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPlethysmography, Impedance-
dc.subject.MESHRegional Blood Flow-
dc.subject.MESHSphygmomanometers-
dc.titleMeasurement of leg arterial compliance of normal subjects and diabetics using impedance plethysmography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthorDEOK WON KIM-
dc.contributor.googleauthorSOO CHAN KIM-
dc.identifier.doi10.1111/j.1749-6632.1999.tb09457.x-
dc.contributor.localIdA00376-
dc.relation.journalcodeJ00181-
dc.identifier.eissn1749-6632-
dc.identifier.pmid10372158-
dc.identifier.urlhttps://nyaspubs.onlinelibrary.wiley.com/doi/full/10.1111/j.1749-6632.1999.tb09457.x-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.affiliatedAuthor김덕원-
dc.citation.volume873-
dc.citation.number1-
dc.citation.startPage112-
dc.citation.endPage120-
dc.identifier.bibliographicCitationAnnals of the New York Academy of Sciences, Vol.873(1) : 112-120, 1999-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.