dc.description.abstract | During intraocular surgery including cataract,air bubbles occasionally enter the anterior chamber during irrigation. The influences of these air bubbles on the cornea endothelium,however,have yet to be known.The purpose of this study is to investigate the effects of bubbles on the rabbit corneal endothelium during irrigation and aspiration mode in experimental phacoemulsification. After anesthesia,the anterior chamber was irrigated and aspirated for 1 minute with balanced salt solution.The rabbits were then randomly divided into 4 groups. In group 1,corneal endothelial irrigation and aspiration were performed without air bubbles for 1 minute.In group 2,corneal endothelial irrigation was performed in the presence of air bubbles in the anterior chamber for 1minute.In group 3,corneal endothelial irrigation and aspiration were performed in the presence of air bubbles in the anterior chamber for 1minute.In group 4,corneal endothelial irrigation was performed with silicone oil at 50 ㎜Hg pressure in the presence of air bubbles in the anterior chamber for 1 minute. In group 1,the cornea endothelial cells showed normal F-actin without cell damage.In group 2,a ring shaped endothelial cell destruction area adjacent to the border was found along the margin of the air bubble.In group 3, similar ring-shaped lesion found in group 2 were observed but with more extensive cell destruction.In group 4,a partial number of cell to cell separation was found without endothelial cell destruction. In conclusion,air bubbles in the anterior chamber during irrigation with balanced salt solution showed destructive changes in rabbit corneal endothelial cell. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한안과학회 | - |
dc.relation.isPartOf | Journal of the Korean Ophthalmological Society (대한안과학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 안과용 평형염액의 안내관류시 유입된 기포가 각막내피세포에 미치는 영향 | - |
dc.title.alternative | Effects of Air Bubble on the Corneal Endothelium | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학교실) | - |
dc.contributor.googleauthor | 김응권 | - |
dc.contributor.googleauthor | 박중원 | - |
dc.contributor.googleauthor | 김형래 | - |
dc.contributor.googleauthor | 이영기 | - |
dc.contributor.googleauthor | 강신정 | - |
dc.contributor.googleauthor | 임지현 | - |
dc.contributor.localId | A00831 | - |
dc.relation.journalcode | J01838 | - |
dc.identifier.eissn | 2092-9374 | - |
dc.subject.keyword | Air bubble, Balanced salt solution | - |
dc.subject.keyword | Corneal endothelium | - |
dc.subject.keyword | F-actin | - |
dc.subject.keyword | Phacoemulsification | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | 김응권 | - |
dc.citation.volume | 40 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1480 | - |
dc.citation.endPage | 1486 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Ophthalmological Society (대한안과학회지), Vol.40(6) : 1480-1486, 1999 | - |